8 Troubleshooting Guide

Troubleshooting - What to check when problems occur:
PROBLEM
The unit frosts up.
Water is leaking out the back of the
unit.
Ice cubes sticking together
Noise during operation
No ice
Not enough ice
Water leaks into ice bucket.
14
POSSIBLE CAUSE
Unit is manual defrost model.
Door gasket not sealing properly
High ambient temperatures or
humidity
Door left open
Water supply connection leaking
Door gasket not sealing properly
Infrequent use of cubes
Copper water supply tubing
contacting internal components
Certain sounds are normal.
Fan blade touching obstruction
(wiring, foam insulation, etc.)
Bin arm locked in upright position
No water to unit
Control set too cold
Ice cube size too large
Dirty condenser coils
Water level set too high
SS1095
MARINE SERIES
DANGER
ELECTROCUTION HAZARD! Never attempt to repair
or perform maintenance on the unit unitl the main
electrical power has been disconnected.
REMEDY
Defrost unit manually (See MAINTENANCE;
DEFROSTING).
Adjust door (See MAINTENANCE; DOOR ALIGN, ADJUST,
REVERSE).
Defrost unit manually (See MAINTENANCE;
DEFROSTING).
Make sure door is closed.
Tighten fitting as required.
Adjust door (See MAINTENANCE; DOOR ALIGN, ADJUST,
REVERSE).
Break apart cubes.
Carefully bend tubing away from cabinet and
components.
Soft sounds from the fan and water/dropping sounds
from the ice maker will be heard.
Remove obstruction.
Lower bin arm.
Turn on water or contact plumber.
Adjust control to a warmer setting (See OPERATION).
Set cube size smaller (See MAINTENANCE; ICE MAKER;
ICE CUBE THICKNESS ADJUST).
Clean condenser (See MAINTENANCE; CONDENSER
CLEANING).
Set cube size smaller (See MAINTENANCE; ICE MAKER;
ICE CUBE THICKNESS ADJUST).