1 DESCRIPTION

The FD3-PMFC06, shown in
for the small size FDH 3000 cabinet when installed in a concrete pad foundation.
Caution: Mounting the cabinet directly on a concrete pad may cause chemical corrosive action
to the cabinet. Use only the Pad Mount Frame (PMF) as a mounting base for the cabinet. Do
not use caulking compounds as a sealer between the cabinet and the PMF.

2 INSTALLATION RECOMMENDATIONS

The site chosen for the installation must conform to all local codes and any permits required
must be obtained prior to the start of installation. The location must be accessible and provide
adequate parking for worker and vehicle safety. Situate the concrete pad along the trench that
was used for routing the OSP fiber cables for the system. The installed cabinet must not create a
visual or physical obstruction to vehicular or pedestrian traffic. Ensure that there is sufficient
space on all sides to facilitate cabinet installation. Depending on the landscaping requirements,
the top surface of the concrete pad may be located from 0 to 3 inches (7.6 cm) above the
surrounding grade.

3 BASE CONSTRUCTION AND CONDUIT INSTALLATION

Prepare a base for the concrete pad that meets all local code requirements. The base must have a
footing of 4 to 6 inches (10.2 to 15.2 cm) of gravel or other suitable fill (per local practice) on
firmly compacted soil. Refer to the diagram shown in
Note: Use crushed rock 3/8-inch or less in size mixed with stone dust (per local practice)
to for the base. The name of the material may differ in different geographical areas.
Possible names are Class 5, stone dust, aughts (0s) and ones (1s), or stone aggregate
Figure
1, is a stainless steel frame that provides a mounting base
20.80 IN.
(52.8 CM)
Figure 1. FD3-PMFC06 Dimensions
ADCP-96-123 • Issue 1 • May 2007
5.5 IN.
(14.0 CM)
12.55 IN.
(31.2 CM)
Figure 2
for the base construction details.