Download Print this page

Panasonic FV-07VB1 Supplementary Installation Instructions page 7

Contractor pack
Hide thumbs Also See for FV-07VB1:

Advertisement

INSTALLATION FOR FV-07VBB1
1. Insert the blower / motor assembly by sliding it into
adaptor flanges. Then press lock the blower / motor
assembly into the housing can until the blower
"clicks" into place for temporary fixation. (Fig.8)
2. Secure the blower / motor assembly with 2 screw
and connect the molex plug connector from the
blower to the junction box. (Fig.9)
CAUTION
Before turning on the fan, make sure the
connector is inserted at the correct position.
Failure to properly connect will result in fan not
working.(Fig.9)
The claw of connector must latch to the rib
completely.(Fig.9)
WARNING
The blower / motor assembly must be installed
into housing can tightly by the 2 screw . failure
to secure with screw will affect the grounding.
3. Insert the grille assembly mounting springs into the
slots as shown and mount grille assembly to fan body .
(Fig.10)
WARNING
CAUTION
1. Remove grille assembly. (Squeeze mounting springs
and pull down carefully.)(Fig.11)
2.Wash and clean grille assembly.
(Use non-abrasive kitchen detergent, wipe dry with
clean cloth.)(Fig.12)
3. Remove dust and dirt from fan body using a
vacuum cleaner. (Fig.13)
4. Using a cloth dampened with kitchen detergent,
remove any dirt from Fan Body. Wipe dry with
clean cloth. (Fig.14)
5. Replace grille assembly.
Adaptor
flanges
Blower / motor assembly
Plug connector
Rib
Claw
2 Screw
(ST4.2X8)
Fan body
Glove
Glove
Ceiling
Ceiling
Fig.8
Ceiling
Fig.9
Slot
Mounting
spring
Grille assembly
Fig.10
Slot
Mounting
spring
Grille assembly
Fig.11
Fig.12
Vacuum
cleaner
Fig.13
Ceiling
Glove
Fig.14
7

Advertisement

loading