Panasonic FV-07VF1 Installation Instructions Manual
Panasonic FV-07VF1 Installation Instructions Manual

Panasonic FV-07VF1 Installation Instructions Manual

Ceiling mounted ventilating fan

Advertisement

INSTALLATION
INSTRUCTIONS
Ventilating Fan
READ AND SAVE THESE INSTRUCTIOINS.
Please read these instructions carefully before attempting to install,
operate or service the Panasonic Ventilating Fan. Failure to comply
with instructions could result in personal injury and/or property
damage. Please retain this booklet for future reference.

Table of Contents

II
III
FV-05VF1 FV-07VF1
FV-09VF1 FV-11VF1
2
2
3
4
4
4-5
6-8
8-9
9-12
12-13
13-14

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic FV-07VF1

  • Page 1: Table Of Contents

    READ AND SAVE THESE INSTRUCTIOINS. Please read these instructions carefully before attempting to install, operate or service the Panasonic Ventilating Fan. Failure to comply with instructions could result in personal injury and/or property damage. Please retain this booklet for future reference.
  • Page 2: Supplied Accessories

    DESCRIPTION DESCRIPTION These Panasonic ceiling mount ventilating fan models use a low noise sirocco fan driven by a capacitor motor. The motor is designed to have an extended service life with reduced energy consumption. It also incorporates a thermal-cutoff for safety. The grille covering the main body is a spring-loaded,quick-remove type.
  • Page 3: Dimensions

    DIMENSIONS FV-05VF1 FV-07VF1 FV-09VF1 FV-11VF1 3 3 0 ( 1 3 ) 2 5 5 . 6 ( 1 0 1 / 1 6 ) Grille Adaptor Junction box Junction box cover Body Damper 1 0 5 ( 4 1 / 8 ) 56.7 (2 1/4)
  • Page 4: Specifications

    SPECIFICATIONS SPECIFICATIONS Model No. Air direction FV-05VF1 FV-07VF1 Exhaust FV-09VF1 FV-11VF1 * At 0.0" Static pressure, (Pa) UNPACKING UNPACKING Unpack and carefully remove unit from carton. Refer to the Supplied Accessories list to verify that all parts are present. GENERAL SAFETY INFORMATION GENERAL SAFETY INFORMATION 1.
  • Page 5 GENERAL SAFETY INFORMATION CONTINUED GENERAL SAFETY INFORMATION CONTINUED CAUTION: 1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. Not for use in cooking area. (Fig .B) 3. This product must be properly grounded. WARNING: To reduce the risk of fire, electric shock or injury to persons, observe the following;...
  • Page 6: Installation I (Joist Mounting)

    Mount junction box cover carefully so that lead wires are not pinched. 5.Install circular duct (4 inch) or optional part (3 inch adaptor connector) that is only for FV-05VF1 and FV-07VF1 and secure it with duct tape. Connection method for 3 inch adaptor connector...
  • Page 7 INSTALLATION I (JOIST MOUNTING) CONTINUED INSTALLATION I (JOIST MOUNTING) CONTINUED 6. Remove ceiling section. (Fig.4) 7. Insert fan body into ceiling. (Fig.6) IMPORTANT: Make sure that body "Claws" are property inserted into adaptor slots. 8. Secure fan body to adaptor using two thumb screws.(Fig.7) 9.
  • Page 8: Installation Ii (Wooden Header)

    INSTALLATION I (JOIST MOUNTING) CONTINUED INSTALLATION I (JOIST MOUNTING) CONTINUED 10. Secure fan body to ceiling joists using long screws in horizontal direction with suspension bracket II and III.(Fig.9) 11. Secure suspension bracket II and III to the fan body using 2 screws(Fig.10) 12.
  • Page 9: Installation Iii (In Existing Construction)

    INSTALLATION II (WOODEN HEADER) CONTINUED INSTALLATION II (WOODEN HEADER) CONTINUED 2. Install header between ceiling joists using nails or screws. 3. Install the ventilating fan and secure with screws.(Fig.13 and Fig.14) 4. Insert the circular duct to the adaptor. Remove the junction box cover and secure conduit to junction box knockout hole (7/8 inch) (Fig.14 ) 5.
  • Page 10 Suspension bracket II Suspension bracket I Install circular duct(4 inch) or optional part (3 inch adaptor connector) that is only for FV-05VF1 and FV-07VF1 and secure it with duct tape as shown in Fig.17. mm (inches) Black...
  • Page 11 INSTALLATION III (IN EXISTING CONSTRUCTION) CONTINUED Remove the 2 square knock-out carefully from surface of the frame by screw driver ( Fig.19) .And remove the bracket cover on the other side of the frame body. Insert fan body into ceiling as shown in Fig.20. Secure the fan body to the adaptor by using one thumb screw as shown in Fig.21 Replace with clamp plates(accessories) and secure the fan...
  • Page 12: Maintenance

    INSTALLATION III (IN EXISTING CONSTRUCTION) CONTINUED Insert the blower into the fan body.(Fig.23) Secure blower to fan body with screws that were loosen before.(Fig.24) Mount the fan body with thumb screw (on the right side of bottom of the adaptor) as shown in Fig.7 of page 7. Connect plug connector to receptacle.(Fig.8 of page 7.) Insert mounting springs into slots as shown and mount grille to fan body.(Fig.11 of page 8.)
  • Page 13: Product Service

    However, should your unit ever require service, a nationwide system of factory service centers and AUTHORIZED INDEPENDENT SERVICE CENTERS is maintained to support your product's warranty. (In the U.S.A.,call 1-866-292-7292 to locate the Panasonic Authorized Service Center nearest you.) Cleaner Fig. 27...
  • Page 14 PANASONIC CONSUMER ELECTRONICS COMPANY One Panasonic Way, Secaucus, NJ, 07094 PANASONIC CANADA INC. 5770 Ambler Drive, Mississauga, ON L4W 2T3...

This manual is also suitable for:

Fv-05vf1Fv-09vf1Fv-11vf1

Table of Contents