Figure 2-16. Factory Internal Reference Configuration

Analog Output Polarity Selection

Each analog output channel can be configured for either unipolar or bipolar output. A unipolar
configuration has a range of 0 to V
-V
to +V
at the analog output. V
ref
ref
output circuitry and can either be the 10 V onboard reference or an externally supplied reference
between -10 V and +10 V. Both channels need not be configured the same way; however, at the
factory both channels are configured for bipolar output.

Bipolar Output Selection (Factory Setting)

You select the bipolar output configuration for each analog output channel by setting the following
jumpers:
Analog Output Channel 0:
Analog Output Channel 1:
This configuration is shown in Figure 2-17.