Error Code Table - Panasonic SA-NS55P Service Manual

Table of Contents

Advertisement

SA-NS55P
Step
Checking Item
5
Audio Performance
(Tone ON)
6
Audio Performance
(Tone OFF)
7
Test Complete - exit
8.3.

Error Code Table

Self-Diagnosis Function provides information on any problems occuring for the unit and its respective components by displaying
error codes. Thesed error code such as U**, H** and F** are stored in memory and held unless it is cleared.
The error code is automatically display after entering into self-diagnostic mode.
Error Code Diagnosis Contents Description of error
F15
CD REST SW
Abnormal
H15
CD Open SW
Abnormal
F26
Communication
between CD servo
LSI and micro-p
abnormal.
F61
Power Amp IC output
abnormal
Key operation
Press [CLEAR] button on
Test Box + ART20
remote control. To exit,
Press [
] button on main
unit or remote control
Press [PROGRAM] button
Test Box + ART20
on remote control. To exit,
Press [
] button on main
unit or remote control
Press remote [DEL]
-
CD traverse position intial
setting operation failsafe
counter (1000 ms) waiting
for REST SW to turn on.
Error No. shall be clear by
force or during cold start.
During normal operation
CD OPEN SW On fail to
be detected with 4 sec.
Error No. shall be clear by
force or during cold start.
CD function DTMS
command, after system
setting, If SENSE = ´L´
cannot be detected.
Memory shall contain F26
code. After Power on, CD
function shall continue,
error display shall be "NO
DISC". Error No. shall be
clear by force or cold start.
During normal operation, if
DCDET
becomes
"L",
normal
POWER
OFF
process
shall
not
be
executed, PCONT shall be
switched
to
"L"
immediately. "GOODBYE"
shall not be display but the
error
display
F61
is
displayed
instead.
2
seconds
after
the
F61
displayed, ECONO shall be
set to "L" and FL display
shall be turned off. The
error
content
shall
be
memorized
when
the
abnormality occurs and can
be display in the C-mecha
self-diagnostic
mode
described later.
Device
-
Automatic FL Display
18
FL Display
Result OK
Result Fail
Result OK
Result Fail
Remarks
For CD unit (For Traverse).
Press [
] on main unit for next
error.
For CD unit (For Traverse).
Press [
] on main unit for next
error.
For CD unit (For Traverse).
Press [
] on main unit for next
error.
For Power Supply Related Error
Detection.
Press [
] on main unit for next
error.

Advertisement

Table of Contents
loading