Basic Operation
Resettable Input Circuit Breaker: Protects your electrical circuit from overcurrent draw from the UPS load. If this breaker trips, remove some of the load,
8
then reset it by pressing it in.
"ECO CONTROL" Button: Use this button
9
"ECO STATUS" LED: This green LED
10
turned off the ECO outlets to conserve energy. See the ECO Energy-Saving Feature section for more information.
Surge-Only Protected ECO Outlets: These outlets provide surge and noise protection, but not battery backup. Your UPS system can save energy by
11
automatically turning off these outlets when it detects that your computer is turned off or in standby mode. Make sure that any devices connected to the
ECO outlets can be turned off without interrupting your Internet connection, local network or other essential services. See the ECO Energy-Saving Feature
section for more information.
Battery Replacement (bottom panel, not shown): Under normal conditions, the original battery in your UPS will last several years. Battery replacement
should be performed only by qualified service personnel. During battery replacement, qualified service personnel should refer to "Battery Warnings" in the
Safety section and should observe the following procedure: turn the UPS off, unplug the power cord and remove the two screws on the UPS bottom panel to
access the internal battery. Tripp Lite offers a complete line of replacement batteries at www.tripplite.com.

Storage and Service

Storage
To avoid battery drain, all connected equipment should be turned off and disconnected from the UPS. Press and hold the ON/OFF/TEST switch for one second.
Your UPS will be completely turned off (deactivated), and will be ready for storage. If you plan on storing your UPS for an extended period, fully recharge the
UPS batteries every three months. Plug the UPS into a live AC outlet, turn it on by pressing and holding the ON/OFF/TEST switch for one second, and allow
the batteries to recharge for 4 to 6 hours. If you leave your UPS batteries discharged for a long period of time, they will suffer a permanent loss of capacity.
Service
Before returning your UPS for service, follow these steps: 1. Review the installation and operation instructions in this manual to ensure that the service problem
does not originate from a misreading of the instructions. 2. If the problem continues, do not contact or return the UPS to the dealer. Instead, call Tripp Lite at
(773) 869-1233. A service technician will ask for the UPS's model number, serial number and purchase date and will attempt to correct the problem over the
phone. 3. If the problem requires service, the technician will issue you a Returned Material Authorization (RMA) number, which is required for service. If you
require packaging, the technician can arrange to send you proper packaging. Securely pack the UPS to avoid damage during shipping. Do not use Styrofoam
beads for packaging. Any damages (direct, indirect, special, incidental or consequential) to the UPS incurred during shipment to Tripp Lite or an authorized
Tripp Lite service center is not covered under warranty. UPS Systems shipped to Tripp Lite or an authorized Tripp Lite service center must have transportation
charges prepaid. Mark the RMA number on the outside of the package. If the UPS System is within the 2-year warranty period, enclose a copy of your sales
receipt. Return the UPS for service using an insured carrier to the address given to you by the Tripp Lite service technician.
200804158 93-2806 Economizer UPS System OM.indd 5
(Continued)
to enable or disable the ECO feature. See the ECO Energy-Saving Feature section for more information.
A
lights when the ECO feature has been enabled. The LED blinks every 5 seconds when the UPS system has