Connection Diagram; Application Examples - Siemens RDJ10RF/SET Manual

Wireless room temperature controller with 24-hour time switch and lcd
Hide thumbs Also See for RDJ10RF/SET:
Table of Contents

Advertisement

Connection diagram

Application examples

10/12
Siemens
Building Technologies
L – N AC 230 V / Lx – Nx AC 24...250 V
Wireless room temperature controller with
receiver control of a gas-fired wall-hung
boiler
N1
T
N2
Y1
M1
Wireless room temperature controller with
receiver control of a heating circuit pump
(precontrol by manual mixing valve)
F1
Thermal reset limit thermostat
F2
Safety limit thermostat
M1
Circulating pump
Room temperature controllers
L
Live, AC 230 V
Lx
Live, AC 24...250 V
L1
N.O. contact, AC 24...250 V / 8 (3) A
L2
N.C. contact, AC 24...250 V / 8 (3) A
M1
Circulating pump
N
Neutral conductor
Nx
Neutral conductor
N2
Receiver RCR10/433
Y1
Actuating device
Wireless room temperature controller with
receiver control of atmospheric gas burner
E1
Cooling equipment
N1
Room temperature controller RDJ10RF
N2
Receiver RCR10/433
Y1
3-port valve with manual adjustment
Y2
Magnetic valve