Troubleshooting; Accessories And Kits - Graco 115123 Instructions And Parts List

Lubrication controller
Table of Contents

Advertisement

Troubleshooting

Description
Timer fails to activate solenoid
Pressure switch fails to shut
down system2

Accessories and Kits

Repair Kit 241574
Repair Kit 241574 is available. It contains two junction
box connectors and six rubber grommets, as shown.
308950C
Problem
No power supplied to solenoid
Solenoid faulty
Timer faulty
Low Level alarm
Pressure switch incorrectly wired
Pressure switch faulty
Timer faulty
8856A
Power light off: timer is not receiving power.
Verify connections and verify power supply
Power light on: verify solenoid connections
Replace solenoid
Replace timer
Refill reservoir
Verify proper connections
Replace pressure switch
Replace timer
24V Air Solenoid 114488
9008A
Pressure Switch 115124
9146A
Troubleshooting
Solution
3/8" npt (3)
Manual
Activation
Button
1/4" npt(f)
9

Advertisement

Table of Contents
loading

Table of Contents