Removing The M.2 2280 Solid-State Drive From The Ssd2 Slot - Dell XPS 17 9700 Service Manual

Hide thumbs Also See for XPS 17 9700:
Table of Contents

Advertisement

Steps
1. Align the notch on the solid-state drive with the tab on the SSD2 slot.
2. Slide the solid-state drive into the SSD2 slot.
3. Using the alignment post, place the solid-state drive thermal bracket over the solid-state drive.
4. Align the screw hole on the solid-state drive thermal bracket with the screw hole on the system board.
5. Replace the screw (M2x3) that secures the solid-state drive to the palm-rest and keyboard assembly.
Next steps
1. Install the battery.
2. Install the
base
cover.
3. Follow the procedure in
Removing the M.2 2280 solid-state drive from the SSD2
slot
Prerequisites
1. Follow the procedure in
2. Remove the
base
cover.
3. Remove the battery.
About this task
NOTE:
This procedure applies only to computers shipped with an M.2 2280 solid-state drive installed in the SSD2 slot.
The following image indicates the location of the M.2 2280 solid-state drive that is installed in the SSD2 slot and provides a visual
representation of the removal procedure.
After working inside your
computer.
Before working inside your
computer.
Removing and installing components
23