Starting The Boiler - Bosch Condens 5000W Installation And Maintenance Instructions Manual

Hydronic gas system boiler 18kw
Table of Contents

Advertisement

5.4

Starting the boiler

WARNING:
Running the boiler
▶ Never run the boiler when the system is empty or partially filled.
1
Fig. 57 Control panel overview
[1]
Central heating temperature control
[2]
Burner indicator (green)
[3]
Service button
[4]
Cover or optional Programmer
[5]
Power ON and fault indicator (blue)
[6]
ECO button - not used
[7]
Reset button
[8]
DHW temperature control (only operational when "optional
integral diverter valve" is fitted)
[9]
System pressure gauge
Switching the boiler ON/OFF:
▶ Turn on mains power supply, the power on indicator [5] illuminates
blue.
▶ Turn on any external controls.
▶ Set the thermostatic radiator controls to maximum temperature.
▶ Set the clock/programmer to continuously ON and the room
thermostat to maximum temperature.
▶ Turn the boiler CH temperature control [1] to maximum.
The burner on indicator [2] illuminates green when the burner has lit.
If the boiler fails to light, the blue power indicator [5] and reset
button [7] will flash.
Resetting the boiler if a fault occurs
▶ Do not press the blue power indicator [5] to reset the boiler.
▶ Press and hold the reset button [7] for more than two seconds to
reset the boiler if it fails to light.
Bosch Condens 5000W – 6 720 646 195 (2018/10)
2
3
4
5
6
7
Commissioning
8
9
33