36 | Commissioning AU/NZ Starting the boiler CAUTION: Running the boiler B Never run the boiler when the system is empty or partially filled. Fig. 56 Control panel Switching the boiler on/off: Turn the boiler CH temperature control (1) to maximum. The burner on indicator (2) illuminates green when the B Turn on mains power supply, the power on indicator burner has lit.
(i.e. not a first installation error). This fault finding information is for guidance only. Robert Bosch cannot be held Preliminary electrical system checks are the first responsible for costs incurred by incorrectly electrical checks to be carried out during a fault-finding procedure.
62 | Fault finding and diagnosis AU/NZ Blue light Lockout indication reset button Fault Possible solution/check Slow flash Flashing Ignition lockout B Gas present and at correct pressure? (mostly (reset B Gas valve off, required) – Check that there is 35V d.c. to each solenoid flashes –...
TRANSFORMER ST17 Blue EMS BUS contacts Blue Purple (for FX controls not used) Purple Orange BOSCH 24V CONTROLS Orange PLUG IN POINT Green (NOT USED) Fuse F3, slow T 0.5 A 230V/AC Fuse F2, slow T1.6 A ST18 PRE WIRED LINK...