Specifications

6
01023492 F 06/19
Control Valve
Timer
Overall Conditioner Height
Media Tank Dimensions (D x H)
Filter Media Type
Underbedding
Capacity
1
Freeboard
2
Max. Clear Water (Soluble) Iron
Max. Hydrogen Sulfide
Minimum Alkalinity
pH
Service Flow @ Pressure Drop (Clean Bed)
Normal
3
Maximum
Operating Pressure
Operating Temperature
Electrical Requirements
Power Consumption, Continuous/
Maximum
Drain Flow, Maximum
Backwash Regeneration Time
Eduction
Fast Rinse
Capacity based on 5 gpm (10" unit) and 10 mg/L of dissolved iron.
1
Measured from top of media bed to top of surface of tank threads (backwashed and drained).
2
Max flow rates and pressure drop characteristics have not been certified by the Water Quality Association.
3
For the purposes of plumbing sizing, only the service flow rate and corresponding pressure drop may be used.
10" Fiberglass
HE Control Valve
Electronic
69"
10x54 in.
1.5 ft
Catalytic Carbon
3
Cullsan, 20 lbs.
1000 gallons
18 in
10 ppm
8 ppm
100 ppm
7.0–8.5
5 gpm @ 4 psi
20–60 psi/138–414 kPa
33–120° F/1–49°C
120 Volts/60 Hz
6 Watts/240 Watts
5.5 gpm
1–99 minutes
1–99 minutes
1–99 minutes
10" Quadrahull
HE Control Valve
Electronic
69"
10x54 in.
1.5 ft
Catalytic Carbon
3
Cullsan, 20 lbs.
1000 gallons
18 in
10 ppm
8 ppm
100 ppm
7.0–8.5
5 gpm @ 4 psi
20–60 psi/138–414 kPa
33–120° F/1–49°C
120 Volts/60 Hz
6 Watts/240 Watts
5.5 gpm
1–99 minutes
1–99 minutes
1–99 minutes

Hide quick links: