WARNING!
BEFORE BEGINNING ANY WORK ON THE ELECTRICAL INSTALLA-
TION BE SURE THAT THE CIRCUIT BREAKER IS IN THE "OFF" POSI-
TION TO AVOID DANGER OF ELECTRICAL SHOCK
Correct Installation
AURES
SLIM MULTI
Inlet and
Inlet
outlet at
the bottom
Table I: Recommended Cable
Model Name
5 kW
5.5 kW
6 kW
7 kW
7.7 kW
8 kW
9.5 kW 240V
9.5 kW 230V
9.5 kW
10.5 kW
12 kW 230V
12 kW
• Operating water pressure 0.5-8 bar (7-116 psi) • W ater pressure operated flow switch
• Standard 1/2"Ø compression inlet connection • Top-left and right cable entry • Bottom-left water entry
UNIT DIMENSIONS: HEIGHT 178mm WIDTH 304mm DEPTH 98mm
Outlet
Amper
220V
22.7
5kW
22.7
5kW
27.2
6.0kW
31.8
7.0kW
35.0
7.7kW
36.3
8.0kW
38.6
8.0kW
41.3
9.0kW
43
9.5kW
47.7
10.5kW
52.1
10.9kW
54.5
12.0kW
Incorrect Installation
230V
240V
5.5kW
6kW
5.5kW
6kW
6.5kW
7.1kW
7.6kW
8.3kW
8.4kW
9.1kW
8.7kW
9.5kW
8.7kW
9.5kW
9.5kW
10.7kW
10.3kW
11.3kW
11.4kW
12.5kW
12.0kW
13.0kW
13.0kW
14.2kW
8
Heating
Phases
Elements
2+3
Mono
2.2+3.3
Mono
2.5+3.5
Mono
3+4
Mono
3.3+4.4
Mono
3.8+4.2
Mono
4.5+5
Mono
4+5
Mono
4.5+5
Mono
5.25+5.25
Mono
4+4+4
Mono
4+4+4
3 Phase
Min Field
wire mm
2
4
4
4
6
6
6
6
10
10
10
10
3x4