Pcbs - Daikin RKS46LVMA Removal Procedure

3.5/4.5/4.6/5.0/6.0 kw class, 15000/18000 btu/h class
Hide thumbs Also See for RKS46LVMA:

Advertisement

PCBs

4. PCBs
Warning
Step
1. Remove the main PCB.
1
Disconnect the
connector [S12] and
pull out the clamp.
2
Disconnect the
connector [S10].
3
Pull out the clamp.
16
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Main PCB
[S12]
(R16959)
[S10]
(R16808)
(R16775)
Si001163EA
Points
[S12]: filter PCB
[S10]: filter PCB
When reassembling, make
sure the compressor
harness clamp is securely
fastened.
Top view
Compressor harness
(red, blue, yellow)
(R24309)