Graco Mark V Premium Repair Manual page 26

Electric airless sprayers
Table of Contents

Advertisement

Pressure Control Transducer
Installation
1. Install o-ring (20) and transducer (86) in filter base
(67). Torque to 35-45 ft-lb (47-61 N•m). Install grom-
met onto transducer (86) and transducer into control
box.
40
67
86
20
2. Connect transducer connector (E), and Fast Flush
switch connector to control board (95).
E
ti12999a
26
ti7447a
ti13496a
95
3. Install control box (61) and control panel (68) with
four screws (39).
39
ti13494a
61
4. Connect potentiometer connector (C), and Fast
Flush switch connector to control board.
C
5. Install cover (96) with four screws (38).
96
38
68
ti13722b
ti13493b
3A2333B

Advertisement