2.6.6 TONER DENSITY CONTROL

Overview

There are four modes for controlling toner supply as shown in the following tables.
The mode can be changed with by SP2-921. The factory setting is sensor control 1
mode.
Basically, toner density is controlled using the standard TD sensor voltage (Vts),
toner supply reference voltage (Vref), actual TD sensor output voltage (Vt), and ID
sensor output data (Vsp/Vsg).
SM
Toner Supply Clutch On Time
TD Sensor Output
(Vt)
Vt Reference
Voltage (Vref)
Vt Reference
Voltage Update
Vref Update
ID Sensor Output
(Vsp/Vsg)
TD Sensor Initial
Setting (Vts)
2-37
DEVELOPMENT
Calculation
New Vref
B027D517.WMF
B022/B027