  • Page 1 CS1822 / CS1824 2/4-Port USB3.0 4K HDMI KVMP™ Switch RS-232 Commands User Manual www.aten.com...
  • Page 2: Emc Information

    CS1822 / CS4824 RS-232 Commands EMC Information FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 3: Hardware Connection

    Windows. In order to use this feature to send commands to the CS1822 / CS1824, you must first download and install a HyperTerminal application. For detailed instructions and information about each of the commands provided in this manual, please refer to the CS1822 / CS1824 user manual. Setup...
  • Page 4: Rs-232 Pin Assignments

    CS1822 / CS4824 RS-232 Commands RS-232 Pin Assignments Pin assignments for the CS1822 / CS1824’s rear RJ-11 Serial Port that is used for connecting to a serial terminal are given in the table, below: Note: This RJ-11 female connector is 4P4C.
  • Page 5: Console Login - Hyperterminal

    CS1822 / CS4824 RS-232 Commands Console Login - HyperTerminal Once a physical connection from the computer to the CS1822 / CS1824 has been made, you can establish a HyperTerminal session using the instructions below. 1. Open the HyperTerminal application, and configure the port settings for COM1 port, then click OK.
  • Page 6 RS-232 commands to control the switch from the computer. When RS-232 control is enabled via the Open + [Enter] command, the CS1822 / CS1824’s front panel pushbuttons and hotkeys (excluding the mouse cursor shift and monitor layout hotkeys) will be disabled, until the serial connection is closed.
  • Page 7 The Open and Close commands allows you to start and end the link between the computer sending RS-232 commands and the CS1822 / CS1824. When the link is open, the CS1822 / CS1824 only accepts RS-232 commands and will not respond to front panel pushbuttons and hotkeys (excluding the mouse cursor shift and monitor layout hotkeys) –...
  • Page 8: Switch Port Commands

    Parameters: Command Description Switch Port Command Control Description Input Port Number xx= 01~02 (CS1822) / 01~04 (CS1824) Enter Description Enter Enter and send out command Switch Port Commands Some available formulas for the Switch Port commands are as follows: 1. Command + Control + [Enter]...
  • Page 9: Set Baud Rate

    CS1822 / CS4824 RS-232 Commands Set Baud Rate The Set Baud Rate command allows you to configure the baud rate setting for the serial port connection. The default baud rate is 19200. Use the Formula - to set Parameters - to create a Command.
  • Page 10: Keyboard Language Layout

    CS1822 / CS4824 RS-232 Commands Keyboard Language Layout The Keyboard Language Layout command allows you to change the keyboard language layout. The default language is English. Use the Formula - to set Parameters - to create a Command. Formula: Command + Control + [Enter]...
  • Page 11: Hotkey Setting

    CS1822 / CS4824 RS-232 Commands Hotkey Setting The Hotkey Setting command allows you to change the hotkey used to invoke the HSM (Hotkey Setting Mode). The default hotkey is [Num Lock] + [-]. Use the Formula - to set Parameters - to create a Command.
  • Page 12: Hotkey Switching

    CS1822 / CS4824 RS-232 Commands Hotkey Switching The Hotkey Switching command allows you to change the hotkey used for switching. The default hotkey is [Scroll][Scroll]. Use the Formula - to set Parameters - to create a Command. Formulas: Command + Control + [Enter]...
  • Page 13: Usb Reset

    CS1822 / CS4824 RS-232 Commands USB Reset The USB Reset command allows you to reset the USB connection. The default USB reset setting is off. Use the Formula - to set Parameters - to create a Command. Formulas: Command + Control + [Enter]...
  • Page 14: Restore Default Settings

    Restore Default Value Command The available formula for the Restore Default Settings command is as follows: 1. Command + Control + [Enter] For example, to restore all CS1822 / CS1824 settings back to the default, type the following: reset on [Enter]...
  • Page 15: Firmware Upgrade Command

    CS1822 / CS4824 RS-232 Commands Firmware Upgrade The Firmware Upgrade command allows you to enable the firmware upgrade mode. The default setting is off. Use the Formula - to set Parameters - to create a Command. Formulas: Command + Control+ [Enter]...
  • Page 16: Kvm Status

    KVM Status Command The available formula for the KVM Status command is as follows: 1. Command + Control + [Enter] For example, to display the CS1822 / CS1824’s configuration status, type the following: status on [Enter] A message similar to the one below will then appear:...
  • Page 17: Audio Mixer

    The available formula for the Audio Mixer command is as follows: 1. Command + Control + [Enter] For example, to enable the CS1822 / CS1824’s audio mixer for audio port 01 and audio port 02, type the following: audio ron 01 02 on [Enter]...