N-Setting Defrost Lockouts - Traulsen TU044HT Owner's Manual

Traulsen undercounter refrigerators/undercounter freezers owner manual
Table of Contents

Advertisement

VII. n - SETTING THE DEFROST LOCKOUTS:
The defrost lockout parameters allow the customer to prevent the unit from going into a defrost cycle for two hours during
a set time frame. Customers can set up to four defrost lockout parameters. They are all programmed the same way. The
parameters will be set for the time the lockout is to start. The controller automatically calculates 2 hours from that setting.
The options are similar to the 24-hour clock settings and are in 30-minute increments. Each of the lockout parameters cov-
ers 6 hours of the 24-hour clock. Note: The 24-hour clock must be set for this feature to operate at the correct time of day.
See "Setting the 24-Hour Clock" on page 11.
Sample:
OFF
020 = 2:00 a.m.
023 = 2:30 a.m.
030 = 3:00 a.m.
033 = 3:30 a.m.
040 = 4:00 a.m.
043 = 4:30 a.m.
050 = 5:00 a.m.
053 = 5:30 a.m.
060 = 6:00 a.m.
063 = 6:30 a.m.
070 = 7:00 a.m.
073 = 7:30 a.m.
080 = 8:00 a.m.
A lockout can not be programmed to start at 12:00 am or 12:30 am due to conflicts with other internal programs. The de-
frost lockouts can not be programmed to run back-to-back. For example, if dL1 is set to 080, then a defrost cycle would
be locked out from 8:00 am to 10:00 am. Because of the dL1 setting the dL2 parameter would not let the user choose a
lockout start time before 10:30 am. All lockouts are preset at the factory to OFF.
Follow the instructions to enter the customer access code on page 9. When the control
displays
Thermostat Set High, press the down arrow key
control display reads
The display will show
When the correct time is displayed, press the set button
The display will then read
You can press the up or down arrow keys
or press the alarm cancel button to exit
VII. MICROPROCESSOR CONTROL (continued)
OFF
080 = 8:00 a.m.
083 = 8:30 a.m.
090 = 9:00 a.m.
093 = 9:30 a.m.
100 = 10:00 a.m.
103 = 10:30 a.m.
110 = 11:00 a.m.
113 = 11:30 a.m.
120 = 12:00 p.m.
123 = 12:30 p.m.
130 = 1:00 p.m.
133 = 1:30 p.m.
140 = 2:00 p.m.
Off. Press the arrow keys
.
)
)
)
OFF
140 = 2:00 p.m.
143 = 2:30 p.m.
150 = 3:00 p.m.
153 = 3:30 p.m.
160 = 4:00 p.m.
163 = 4:30 p.m.
170 = 5:00 p.m.
173 = 5:30 p.m.
180 = 6:00 p.m.
183 = 6:30 p.m.
190 = 7:00 p.m.
193 = 7:30 p.m.
200 = 8:00 p.m.
until the control the
or
. Press the set button
to set the start time.
SET
.
or
.
to scroll to the next parameter
-14-
OFF
200 = 8:00 p.m.
203 = 8:30 p.m.
210 = 9:00 p.m.
213 = 9:30 p.m.
220 = 10:00 p.m.
223 = 10:30 p.m.
230 = 11:00 p.m.
233 = 11:30 p.m.
240* = 12:00 a.m.
243* = 12:30 a.m.
010 = 1:00 a.m.
013 = 1:30 a.m.
020 = 2:00 a.m.
* Denotes not available.
.
SET

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tu044ltTu072htTu072ltTu100ht

Table of Contents