Wiring Diagram; Logic Diagram - Broan FRESH IN FIN-180B Installation Instructions Manual

Basic
Hide thumbs Also See for FRESH IN FIN-180B:
Table of Contents

Advertisement

Available languages

Available languages

4. WIRING DIAGRAM

Risk of electric shock. Electrical wiring must be done by qualified personnel in
accordance with all applicable codes and standards. Before connecting wires, switch
power off at service panel and lock service disconnecting means to prevent power from
J1-2
High Voltage
(120VAC)
J1-1
ELECTRONIC ASSEMBLY
VE0411A
being switched on accidentally.

LOGIC DIAGRAM

F1
Line
Neutral
WIRING DIAGRAM
CFM
Se ng
High
J1
1
1
J10
J2
F1
1
A1
WARNING
CFM Range
CFM Se ng
AC
Line
Filter
CFM Range
Se ng
Low
BLK
WHT
GRN
Power cable
WHT
BLK
ORG
RED
BLU
Control cable
9 9
J10
J2-1
J2-2
WIRING COLOR CODE
BLK
BLACK
BLU
BLUE
GRN
GREEN
ORG
ORANGE
RED
RED
WHT WHITE
W1
120VAC,
60Hz
M1
Supply fan
motor
GRN
Line voltage factory wiring
Low voltage factory wiring
Low voltage field wiring
Ref: 99046030_REV-A
M1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents