Operating Instructions - Fetco HWD-2102 User Manual

With portion control domestic and export version
Hide thumbs Also See for HWD-2102:

Advertisement

To Start:
Follow equipment installation and set up procedures.
If desired, set any custom dispense temperature or dispense volume
 Instructions for setting dispense temperature & volume located on page 5
1. Open water supply valve
2. Power unit "ON" from rear power switch.
3. Unit will fill and heat (up to 20 minutes for a new unit).
-After unit is filled and heated:
4. Ready Lamp will glow green
5. HWD_2102 may be operated when Ready Lamp is "off" (after initial fill).
6. When ready: the white control panel backlight intensity will slowly pulsate.
NOTE the HWD_2102 should be left "ON". The hot water tank is well insulated to control energy loss.
Standby heat loss is ≤100 watts per hour.
HWD_2102 has two dispense modes: MANUAL and PORTION CONTROLLED
To dispense with MANUAL CONTROL—[Press and Hold!]
1) Press UNLOCK/DISPENSE pad for 1-3 seconds to unlock and activate dispensing system
-Border of UNLOCK/DISPENSE pad will change: turning steady red signaling activation
2) Remove finger from pad
-Border of UNLOCK/DISPENSE pad will glow steady red: ready to dispense
3) Press center of UNLOCK/DISPENSE pad to dispense.
-Keep finger on pad until dispense is complete.
-Dispense automatically stops when time out is complete, or if finger is removed.
Multiple dispenses are possible when the UNLOCK/DISPENSE light pad is steady and red colored
Reactivate next dispense portion by retouching pad. Finger must be on pad to dispense.
To dispense with PORTION CONTROL—[Touch and Hold!]
1) Press and hold UNLOCK/DISPENSE pad for 3 seconds to unlock and activate dispensing system.
-Border of UNLOCK/DISPENSE pad will rapidly strobe signaling activation
2) Remove finger from pad
-Selected portion will automatically complete
3) If needed: tap center of UNLOCK/DISPENSE pad to stop dispense.
-Dispense automatically stops when time out is complete, or if pad is tapped again.
_______________________________________________________________________________________________________________
 Dispense is unlocked and will function only when border of UNLOCK/DISPENSE pad is steady red.
The UNLOCK/DISPENSE pad rapidly flashes red if finger remains on it after dispensing without dispensing.
If finger remains on the UNLOCK/DISPENSE pad more than 30 seconds while rapidly flashing red-the
controls "lock out" and READY LIGHT & HEATING LIGHT will flash rapidly to show a fault state.
All controls are disabled during fault state. To clear fault state:
Switch machine "OFF" for about ten seconds, and then toggle back "ON" (Control Reset).
After controls initiate, hot water tank level and temperature are checked by internal electronics-
The "READY" light will activate if digital check is "clear".
NOTE The check and fault clear may take approximately 2 minutes for filled and preheated unit; up to
20-30 minutes for a new and empty unit.
Go to fetco.com for the latest version of all information

Operating Instructions

P119 User Guide HWD-2102
3
REVISED MARCH 2020