1)Open the cover panel
To access controls
1) Remove silicone tap guard first
2) Remove lower face panel
3) Upper face panel next,
4) Top panel last
4
3
1)
TO REMOVE:
Pull silicone
tap guard
down
2
Reinstall covers
-Reverse steps 1-4 (above)
3) To set water portion and temperature controls
Actual portions and temperatures shown are estimated and are influenced by mains flow rate and temperature
Upper Dial (Marked: S3)
Set temperature
Base temperature begins at 78°C/172°F,
and increments in two degree Celsius units.
Add two degrees for each dial position
numerical value in degrees Celsius (°C) to
78° base to a maximum of 96°C/205°F
Unit is factory set at
Reinstall ribbon connector into
CN3
CN-3 if detached.
This connection is the dispense switch
Lower Dials (Marked S1 &S2 )
Set dispense volume
The two lower dials control the hot water volume to
be delivered by setting the dispense time in
seconds.
The timer dials are additive and control flow for 1 to
30 seconds or approximately 40-1200ml (1.3-40.6
fluid ounces.)
36-42 ml/1.2-1.4oz is dispensed in 1 second.
Actual volume delivered is affected by flow rate (the
supply water line pressure). Lower water pressure
or pressure drops may lower flow rate. Higher
pressure will increase flow rate
Unit is factory set at 5 seconds 200ml/6.8oz.
Designs, materials, specifications, physical dimensions, firmware and software protocol for equipment or replacement parts are subject to review and change by FETCO without notice
Go to fetco.com for the latest version of all information

Adjusting Temperature and Dispense Portion

Access the temperature and dispense portion with three rotary switches
Dials are marked
S3 TH (temperature)
S2 time(x) 1
S1 time(x) 10
To access rotary switches for adjusting
Unplug the machine before disassembly or changing settings
-Turn off power
-Pull off silicone tap guard
-Remove all screws and panels to access control board for adjustments.
-Temperature and portion dials are located under upper face panel (#3)
See below for settings & make adjustment(s)
Reinstall and tighten all screws before power-up
Do not operate until all covers and screws in place.
NOTICE: Reinstall ribbon connector into CN-3 if it is detached-SEE BELOW
After adjusting dials, or following reassembly and plugging in.
1)Switch machine "OFF" for about ten seconds
2) Toggle back "ON" (Control Reset)
96°C/205°F.
.
2) Accessing control settings
}
(portion)
IMPORTANT When Changing Settings:
8
7
9
0
6
5
1
2
4
3
8
7
9
0
6
5
1
2
4
3
8
7
9
0
6
5
1
2
4
3
P119 User Guide HWD-2102
5
Dial Settings for
Temperature
Upper dial
Temperature
Deg. C
Setting
0
78
1
80
2
82
3
84
4
86
5
88
6
90
7
92
8
94
9
96
Dial Settings for
Dispense Volume
Bottom
Top
Sec
0+ 0=
1
0+ 1=
1
0+ 5=
5
0+ 6=
6
1+ 5=
15
2+ 5=
25
3+ 0=
30
Volumes above are an example at typical
0.34MPa/50PSI water pressure.
REVISED MARCH 2020
Deg. F
172
176
180
183
187
190
194
197
201
205
ml
oz
40
1.4
40
1.4
200
6.8
240
8.1
600 20.3
1000 33.8
1200 40.6