Cable types and minimum thicknesses

CABLE LENGTH (m)
230 V AC Power supply
230 V AC Flashing light
TX Photocells
RX photocells
Command and control devices
Antenna
*no. = see product mounting instructions - Warning: the cable section is merely indicative as it depends on the motor power and cable length.
When operating at 230 V and outdoors, use H05RN-F-type cables that are 60245 IEC 57 (IEC) compliant; whereas indoors, use H05VV-F-type cables that
are 60227 IEC 53 (IEC) compliant. For power supplies up to 48 V, you can use FROR 20-22 II-type cables that comply with EN 50267-2-1 (CEI).
To connect the antenna, use the RG58 (we suggest up to 5 m).
For combined connection and CRP, use a UTP CAT5-type cable (up to 1,000 m long).
If cable lengths differ from those specified in the table, establish the cable sections depending on the actual power draw of the connected devices and
according to the provisions of regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, the dimensions on the table need to be recalculated according to the actual power draw and
distances. For connecting products that are not contemplated in this manual, see the literature accompanying said products
< 10
3G x 1.5 mm²
2 x 1.5 mm²
2 x 0.5 mm²
4 x 0.5 mm²
*n° x 0.5 mm²
from 10 to 20
3G x 1.5 mm²
2 x 1.5 mm²
2 x 0.5 mm²
4 x 0.5 mm²
*n° x 0.5 mm²
RG58 max 10 m
from 20 to 30
3G x 2.5 mm²
2 x 1.5 mm²
2 x 0.5 mm²
4 x 0.5 mm²
*n° x 0.5 mm²