Setting
Data
Value
(Hex)
0
10C8
R
1
011C
SS1
2
021C
SS2
3
041C
SS3
4
081C
SS4
5
20C8
F
6
201B
RES
7
C0C9
ST
8
0CC8
JOG selection
9
081A
Accel / decel #1/#2 selection
10
101B
Emergency off
11
021B
DC injection braking ON/OFF
12
041B
Fundamental parameter
switching (V/F #2)
13
011B
Feedback control ON/OFF
14
10CE
Pattern run selection #1
15
20CE
Pattern run selection #2
16
40CE
Pattern run selection #3
17
80CE
Pattern run selection #4
18
02CE
Pattern run continue signal
19
01CE
Pattern run step trigger signal
20
0AC9
JOG forward run
21
06C9
JOG reverse run
22
10AE
Binary bit #0
23
20AE
Binary bit #1
24
40AE
Binary bit #2
25
80AE
Binary bit #3
26
01AF
Binary bit #4
27
02AF
Binary bit #5
In order for binary bit #0 ∼ #10 (setting values 22 ∼ 32) and UP/DOWN frequency setting (setting values 34 &
Note:
35) inputs to be valid, parameter FREQUENCY PRIORITY SELECTION #1 or FREQUENCY PRIORITY
SELECTION #2 in GROUP:FREQUENCY SETTING PARAMETERS must be set to 5 (BIN (binary setting or
UP/DOWN setting)).
Table 9: Input Terminal Selections
Function
(reverse run)
(preset speed selection)
(preset speed selection)
(preset speed selection)
(preset speed selection)
(forward run)
(fault reset)
(gate ON/OFF)
Setting
Data
Value
(Hex)
28
04AF
Binary bit #6
29
08AF
Binary bit #7
30
10AF
Binary bit #8
31
20AF
Binary bit #9
32
40AF
Binary bit #10
33
04CE
No effect
34
01C7
UP/DOWN frequency setting (UP)
35
02C7
UP/DOWN frequency setting
(DOWN)
36
04C7
UP/DOWN frequency clear
37
08C7
PUSH-type RUN key
38
10C7
PUSH-type STOP key
39
02B9
No effect
40
C0C8
Forward/reverse run selection
41
20C7
RUN
42
30C9
Binary data write
43
0198
[LOCAL/REMOTE] key
44
0298
[MON] key
45
0498
[PRG] key
46
0898
[UP] key
47
1098
[DOWN] key
48
2098
[READ/WRITE] key
49
4098
[RUN] key
50
8098
[STOP/CLEAR] key
51
08CE
Commercial power / inverter
switching signal
52
40C7
Reserved for option use
53
10CB
RR frequency switching input
54
20CB
IV frequency switching input
73
Function