WaRNiNg:
ElECtRiCal ShOCK CaN CaUSE DEath OR
iNjURy. aVOiD tOUChiNg ExPOSED CONDUCtORS
OF ElECtRiCity.
additional Multimeter Precautions
1.
Do not test voltage on circuits higher than 750 volts AC or 1000
volts DC.
2.
Do not test current on circuits higher than 1000 amps.
3.
It is safer to test current using the Transformer Jaws, not with
the test leads. Remove test leads when measuring current.
4.
Be careful not to apply voltage to the Test Leads when they are
connected to the COM (common) and Volt/Ohm Jacks and the
Multimeter is in the Ohms testing setting. Damage can occur
to the multimeter.
5.
Do not switch between testing modes with the multimeter
connected to a circuit.
Volt/ Ohm
jack
COM
jack
Ext
200 Ohm/
jack
Continuity Setting
1.
The Data Hold function is used to keep the display reading the same after
the measurement is finished. Press and release the data hold button to
keep displaying the current measurement.
2.
Press and release the Data Hold button again to resume normal operation.
SKU 42396/95652
Operation

Control layout

DC Volt
aC Volt
Setting
Setting
20K Ohm
Setting
Data hold Function
For technical questions, please call 1-800-444-3353.
aC amp
Settings
insulation
test
Settings
Data hold
transformer
jaws
Page 5