Control Layout; Ac Voltage Measurements; Dc Voltage Measurements - CEN-TECH 69096 Operating Instructions Manual

7 function digital multimeter
Hide thumbs Also See for 69096:
Table of Contents

Advertisement

4.
Be careful not
to apply voltage
to the Test Leads
when they are
c o n n e c t e d
t o
t h e
( B o t t o m ) a n d
VΩmA (Center)
Jacks and the
Multimeter is in
an Ohms testing
setting. Damage
can occur to the multimeter
or the fuse may blow.
5.
Do not switch between
testing modes with the
multimeter connected to a
circuit.
Measure AC conductors carrying up to 750 VAC, 45-450 Hz.
1.
Turn the Range Selector Switch to 750 ACV setting.
Always start with the highest range if the voltage is unknown.
2.
Plug the red lead into the
the COM (Bottom) Jack. Switch the Multimeter ON.
3.
Carefully touch the exposed conductors with the tips of the probes to measure
the voltage (not amperes).
4.
Read measurement.
If the voltage is less than 200 volts, set the Range Selector Switch to the
lower range.
5.
When testing is complete, remove Test Leads and store with multimeter.
Measure DC conductors carrying up to 1000 VDC.
1.
Turn the Range Selector Switch to 1000 DCV setting.
2.
Follow the directions above under "AC Voltage Measurements", only use
the DC settings instead.
SKU 69096
For replacement parts, please call 1-800-444-3353.
DC Volt
Selection
Area
Ohm
C O M
Selection
Area
Transistor
/hFE Jack

AC Voltage Measurements

VΩmA

DC Voltage Measurements

Control Layout

AC Volt Selection Area
ON/OFF
Switch
Diode
Selection Area
(Center) Jack. Plug the black lead into
Battery
Test
Selection
Area
DC AMP
Selection
Area
10A
Selection
Area/Jack
Transistor
Selection
Area
Volt/Ohm/
COM Jack
mA Jack
Page 5

Advertisement

Table of Contents
loading