Drainage Hose On The Siphon Blocked; Filter In The Water Inlet Hose Blocked.22 - Siemens XQG62-WS12K2601W Instruction Manual And Installation Instructions

Table of Contents

Advertisement

Cleaning and maintenance
en
Close service flap. If required,
7.
engage disengaged service flap
beforehand.
To prevent unused detergent
Note:
from flowing into the outlet during the
next wash: Pour 1 litre of water into
dispenser II and start the Spin
programme.
Drainage hose on the siphon
blocked
Turn the programme selector to $
1.
Off. Pull out the mains plug.
Residual water may run out!
Note:
Loosen hose clip, carefully remove
2.
drainage hose.
Clean drainage hose and siphon
3.
spigot.
Re-attach drainage hose and secure
4.
connection point with hose clip.
22
Filter in the water inlet hose
blocked
First, release water pressure in the
supply hose:
Turn off the tap!
1.
Select any programme (except Spin
2.
programme).
Select Start/Reload. Leave
3.
programme for approx. 40 seconds.
Switch off the appliance. Pull out the
4.
mains plug.
Clean the filter:
5.
Disconnect the hose from the water
tap.
Clean filter with small brush.
and/or:
Remove hose from the rear of the
appliance.
Take out filter with pliers and clean.
Connect the hose and check for
6.
leaks.