Starting Safety Operating Logic; Checking The Starting Relay - APRILIA SL Mille Workshop Manual

Hide thumbs Also See for SL Mille:
Table of Contents

Advertisement

SL mille
6.6.2 STARTING SAFETY OPERATING LOGIC
NOTE
With the engine shutoff switch in position "JXt"
the starter motor does not turn over.
ELECTRIC SYSTEM
PULLED UP
UP
,OFF
RELEASED
IN NEUTRAL
PULLED UP
TURNING OVER
DOWN
ON
WORKING
RELEASED
PULLED UP
UP
OFF
RELEASED
GEAR ENGAGED
PULLED UP
NOT TURNING OVER
DOWN
ON
NOT WORKING
- RELEASED
6.6.3 CHECKING THE STARTING RELAY
In order to check the operation of the relay:
• Remove the rear fairing, see 7.1.33 (REMOVING THE
REAR FAIRING).
• Disconnect the two-way connector (1) (coloured white).
Upon reassembly, make sure that the electric con-
nector (1) is correctly coupled.
• Lift the relay and slip it off the relevant couplings (2).
• Slip off the two rubber protections (3) (4).
• Disconnect the cables (5) (6) from the relevant termi-
nals on the relay (2).
• From the relay side, power the two internal terminals of
connector (1) at 12V.
• Using a tester (acting as ohmmeter), check the for
breaks between the two screw contacts on the relay
(2).
Correct value with relay powered: 0
Q.
Correct value with relay not powered:
00
Q.
If the resulting values do not correspond to those in-
dicated, change the relay (2).
Release 00/2001-05 - - - - - - - - - -