Battery Charger (Nbb-724) - JRC JSS-2150 Instruction Manual

Mf/hf radio equipment
Hide thumbs Also See for JSS-2150:
Table of Contents

Advertisement

Options Operation

10.3 Battery charger (NBB-724)

The batteries, except for sealed lead-acid batteries that require no
equalization, should be carried out the equalizing charge at least every six
months
1.
AC breaker ················ When turned on, enables to use the AC mains input.
2.
BATT breaker ············· When turned on, connects the internal circuit to the battery, and
3.
BATT LOW alarm lamp ··· This lamp turns on and the buzzer sounds to indicate low voltage
4.
CHG alarm lamp ········· This lamp turns on (or blinks*) and the buzzer sounds to indicate
5.
FLOAT charge lamp ····· This lamp turns on during the floating charge operation.
6.
EQUAL charge lamp ····· This lamp turns on during the equalizing charge operation.
7.
CHARGE mode switch ··· Changes the charge mode between floating and equalizing charge.
8.
Dimmer control ··········· Adjust the dimmer level.
9.
Current meter ············· Indicates the charge current (+) or discharge current (-).
10. Voltage meter ············· Indicates the output voltage of the battery.
10-4
CAUTION
4
6
1
2
3
5
7
after that turning on the AC breaker enables charging of the
battery.
Note that if detected over discharge of the battery
(approx. 19.5V), this breaker trips automatically.
of the battery (approx. 21.5V).
any one of the following alarms.
・ The BATT breaker is OFF while the AC breaker is ON.
・ Over voltage (equalizing charge voltage + 1.0V)
・ High temperature of the charging circuit (+75℃ )
When AC breaker is OFF and BATT breaker is ON, this
Note
CHG lamp turns on. (This is not a malfunction
8
9