LOCAL CODES

Install and use appliance with care. Follow all
local codes. In the absence of local codes, use
the latest edition of The National Fuel Gas
Code, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
25 West 43rd Street, 4th fl oor
New York, NY 10036
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02169-7471
Quincy, MA 02269
UNPACKING
1. Remove logs and appliance base assem-
bly from carton(s).
COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS
These appliances are approved for installation in the US state of Massachusetts if the fol-
lowing additional requirements are met:
• Un-vented Room Heaters shall be installed in accordance with 527 CMR 30.
• Installation and repair must be done by a plumber or gas fi tter licensed in the Common-
wealth of Massachusetts.
f i r e - p a r t s . c o m
• The fl exible gas line connector used shall not exceed 36 inches (92 centimeters) in length.
• The individual manual shut-off must be a T-handle type valve.
• Unvented appliances may NOT be installed in bedrooms or bathrooms.
• A working smoke detector must be installed in the area where vent-free appliances are
installed.
Seller of unvented propane or natural gas-fi red supplemental room heaters shall provide
to each purchaser a copy of 527 CMR 30 upon sale of the unit.
OPERATION
This fi rebox is designed for use with approved
ANSI Z21.11.2 decorative type unvented room
heaters. (Physical size limitations apply. Refer
to minimum fi rebox requirements supplied
with log heater.) It requires no outside vent-
ing or chimney making installation easy and
inexpensive. When used without the blower,
the fi rebox requires no electricity making it
ideal for emergency backup heat.
FIBER BRICK LINERS
A traditional look with neutral hues that ac-
cent a variety of styles. Lightweight fi ber brick
panels are factory installed.
PLANNING
Plan where you will install the fi rebox. This will
save time and money later when you install
the fi rebox. Before installation, consider the
following:
1. Where the fi rebox will be located. Allow for
wall and ceiling clearances (see Installa-
tion Clearances, Page 11).
4
2. Remove all protective packaging applied
3. Check appliance for any shipping dam-
data plates from the grate as-
sembly. The data plates contain
important warranty and safety
information.

PRODUCT FEATURES

BLOWER ACCESSORY
The circulating models will accept either a
rotary type fan (model BK) or the triple radial
fan blower system (model BK3) accessories.
The blower circulates heated air from the fi re-
box into the room. Use of blower is optional.
OPTIONAL OUTSIDE AIR KIT
The optional AK4 and AK4F air kit provides
additional outdoor air to improve burner ef-
fi ciency and reduce build-up of condensation
in the living space. Follow the instructions
included with the air kit.

LOCATING FIREBOX

2. Everything needed to complete installation.
3. These models CANNOT be installed in a
4. Proper air for combustion and ventilation
SuperiorFireplaces.US.com
NOTE: Do not pick up appliance base as-
sembly by burners. This could damage the
appliance. Always handle base assembly
by grate.
to logs and appliance for shipment.
age. If appliance is damaged, promptly
inform dealer where you purchased the
appliance.
CAUTION: Do not remove the
bedroom unless the maximum BTU rating
of the installed vent-free log set is less
than 10,000 Btu/Hr.
(Page 8).