Rocker
Switch
Wire Nut (3x)
Electrical
(Not Supplied)
Housing
Receptacle
f i r e - p a r t s . c o m
(Supplied)
Prewired Receptacle
and Ground
Figure 12 - Fan Switch-Electrical
Wiring Instructions
1.
Remove electrical cover plate with bush-
ing from fi replace by removing 2 sheet
metal screws as shown in Figure 12.
2.
Slide power source wiring through
electrical bushing opening and electri
cal cover plate and make all necessary
connections.
3.
Slide all wiring connections in electrical
housing as shown in Figure 12.
4.
Secure electrical cover plate with screws
previously removed.
NOTE: Electrical housing and cover plate
have sharp edges. Wear protective gloves.
Decide which way you intend to gain access
into the bottom rear of the fi rebox to install the
blower accessory. The lower front panel can
be removed easily by snapping out the front
with a fl at blade screwdriver. Use caution not
to scratch any surfaces. Models with louvered
front panels can also be removed by inserting
fi ngertips between slots and gently pulling out.
DO NOT FORCE. The panels are actually
held in place by means of a retention dimple
embossed on the edge of removable panels.
900781-00_NC
INSTALLATION
Continued
Sheet
Metal
Screws
Electrical
Electrical
Cover
Bushing
Plate
Outer Wrapper
of Fireplace
Power Source Wiring
(Not Supplied)
To Power
Source
Electrical Cover
Plate and
Electrical Bushing
Fireplace Chassis
Ground
Bushing
SuperiorFireplaces.US.com
Control
Access
Cover
ON/OFF
Lower
Rocker
Panel
Switch
Figure 13 - Accessing Blower Compartment
(Controls Not Shown for Clarity)
Accessibility to the bottom on 36" and 42"
models only, can also be gained through the
access panel Lift access panel out by using
fi nger holes. Blower accessory BK or BK3 can
now be installed.
WARNING: If there is a duplex
electrical outlet installed in the
right side of the bottom of the
fi replace base area (see Figure
14), be sure that the electrical
power to the outlet is turned off
before proceeding with blower
installation. Failure to do this
may result in serious injury.
Duplex Electrical Outlet
Figure 14 - Accessing Duplex Electrical
Outlet Installed in Bottom Right Side of
Firebox