Grounding expansion units
5.1
Dual expansion unit grounding
Grounding
cable
8
Note:
For proper grounding, you must fasten your expansion unit(s)
together. Use the provided braided copper grounding cables and screws
(may be in the rail kit).
If only one expansion unit is being used, go to Step 6, "Installing the
power cables" on page 9.
If two or more expansion units are being used continue with the
following.
Using the grounding kit, fasten the lug, fasten the lug at one end of the
0.25m grounding cable to one of the two threaded inserts (adjacent to
the power supply receptacles as indicated by a ground symbol) at the
back of the expansion unit using the M5 x 0.5-inch screw.
If additional expansion units need to be grounded, continue attaching
the grounding cables from unit to unit, overlaying the hole on one end
of the grounding cable from one to the next.
Multiple expansion unit grounding
Grounding
cables