Installation Tools; Option Components; Communication Modular Connector Cn1 Port 1/Port 2 - YASKAWA SI-EP3 Technical Manual

Ac drive option. profinet
Hide thumbs Also See for SI-EP3:
Table of Contents

Advertisement

Installation Manual
*1
GA700, GA800, CR700, and CH700 drives do not use the ground wire.
*2
GA700, GA800, CR700, CH700, and HV600 drives use two screws only.
*3
LED label has transparent background and white letters. Please make sure that you use the correct label for HV600.

Installation Tools

You can use these tools to install the option to the drive:
• A Phillips screwdriver or slotted screwdriver (blade depth: 0.4 mm (0.02 in), width: 2.5 mm (0.1 in))
• A pair of diagonal cutting pliers.
• A small file or medium-grit sandpaper.
*1
Phillips screw sizes are different for different drive capacities. Prepare different screwdrivers for different
screw sizes.
4

Option Components

Option
A - Connector (CN5)
B - Installation hole
C - LED (NS)
*1
D - LED (MS)
*1
E - PROFINET PCB
F - Software number label
G - Ground terminal (FE) and installation hole
Option LED States on page 10
*1
Refer to
*2
Connect the included ground wire during installation. The ground wire is not necessary for installations on GA700, GA800, CR700,
and CH700 drives.

Communication Modular Connector CN1 Port 1/Port 2

The communication modular connector CN1 on the option is a modular dual RJ45 female connector designated
port 1 and port 2. Port 1 and port 2 are the connection points for a customer-supplied male Ethernet network
communication cable.
YASKAWA SIEP C730600 89E PROFINET Technical Manual
Option Contents
*3
HV600
H - Port 1 LED (10/100)
I - Port 1 (RJ45)
J - Port 1 LED (LINK/ACT)
K - Port 2 LED (10/100)
L - Port 2 (RJ45)
M - Port 2 LED (LINK/ACT)
N - PROFINET cable connection
*2
Figure 4.1 Option
for more information about the LEDs.
4 Option Components
Quantity
1
1
*1
*1
*1
*1
*1
.
9