4.2

Overview: line filter

4.2
In conjunction with a line reactor and an EMC-compliant plant configuration, line filters limit
the electromagnetic emissions from the Power Modules to the limit values of class A1 to
EN 55011.
Optional line filter rows that are coordinated with the power range are also available with the
SINAMICS S120 converter system. These line filters differ with regard to the frequency
range in which they reduce the conducted emissions.
Basic Line Filter for Active Line Modules
Basic Line Filters operate in the frequency range from 150 kHz to 30 MHz. Above all, this
protects the radio services.
Wideband Line Filter for Active Line Modules
Wideband Line Filters also operate in the frequency range from 2 kHz to 150 kHz. They help
reduce low-frequency line reactions, which protects consumers (e.g. electronic devices)
against functional impairments and damage when they are operated on the same network.
Line filters for Smart Line Modules
Line filters for Smart Line Modules operate in the frequency range from 150 kHz to 30 MHz.
Above all, this protects the radio services.
Table 4-1
Basic Line Filter for Active Line Modules
16 kW
36 kW
55 kW
Wideband Line Filter for Active Line Modules
16 kW
36 kW
55 kW
80 kW
120 kW
Line filters for Smart Line Modules
5 kW
10 kW
16 kW
36 kW
Equipment Manual Booksize Cold-Plate Power Sections
Manual, (GH4), Edition 06.2005, 6SL3097-2AJ00-0BP2
Overview
Order number
6SL3000-0BE21-6DAx
6SL3000-0BE23-6DAx
6SL3000-0BE25-5DA0
3SL3000-0BE21-6AAx
3SL3000-0BE23-6AAx
3SL3000-0BE25-5AAx
3SL3000-0BE28-0AAx
3SL3000-0BE31-2AAx
6SL3000-0HE15-0AAx
6SL3000-0HE21-0AAx
6SL3000-0BE21-6DAx
6SL3000-0BE23-6DAx
Line Connection
4.2 Overview: line filter
4-3