Device Pages; Enabling And Disabling Devices - Generac Power Systems PWRcell X7600 Series Owner's Manual

Hide thumbs Also See for PWRcell X7600 Series:
Table of Contents

Advertisement

Operation
3. See
Figure
3-5. Use the up and down arrows to
highlight the desired mode and press the center
button to select it.
Figure 3-5. Selecting Operational Modes (3 of 4)
4. Arrow right and press the center button to select
Confirm.
5. See
Figure
3-6.
Verify the mode listed at the top of
the home screen is the desired mode.
Figure 3-6. Selecting Operational Modes (4 of 4)

Device Pages

Each device connected to the system has its own device
page. The device page contains basic information about
the device, such as its power level and state.
Use the left and right arrow keys to scroll through
device pages.
Press the center button to launch the main menu
for that device.
NOTE: See
Figure
3-7. A Device Offline message
indicates the device is disconnected or has lost
communication with the inverter.
Figure 3-7. Device Pages
12

Enabling and Disabling Devices

Electrocution. Initiate a system-wide safety shutdown
and turn PWRcell Disconnect Switch OFF on all
connected batteries before performing service. Failure
to do so will result in death, serious injury, equipment
and property damage.
Electrocution. Never enable any device during an
installation or while wires are exposed. Doing so
could result in death, serious injury, equipment or
property damage.
009967
NOTE: If a device has never been enabled, it remains
disabled until enabled by a user.
After a power outage, all REbus devices must be enabled
by the user before the device will operate. If a device is
disabled, the device will remain in a disabled state and
will not resume operation until enabled by the user.
Once enabled, if grid power is present the inverter will
create DC voltage, establishing the REbus nanogrid. All
devices connected to REbus will wake up and begin
communications.
To enable a device:
1. Use the right arrow key to scroll to the desired
device page.
2. See
009968
Disabled.
Figure 3-8. Enabling and Disabling Devices (1 of 3)
3. Press the center button.
009969
DANGER
DANGER
Figure
3-8. Verify the device status reads
Owner's Manual for Generac PWRCell Inverter
(000600)
(000627)
009970

Hide quick links: