Operational Modes Overview; Grid Tie; Clean Backup - Generac Power Systems PWRcell X7600 Series Owner's Manual

Hide thumbs Also See for PWRcell X7600 Series:
Table of Contents

Advertisement

General Information

Operational Modes Overview

Generac PWRcell offers several operational modes for
various
installation
configurations,
applications. Connected REbus devices work together to
manage the distribution of power based on the selected
operational mode.
Priority

Grid Tie

1
Support local loads
2
Export to grid
3
-
4
-
Goal
Keep batteries charged as much as possible
Keep batteries charged using only solar power
Net-metering solar energy without a battery
Use grid as little as possible
Never sell power to grid
Grid Tie
In Grid Tie mode, the Generac PWRcell Inverter
functions as a conventional grid-tied inverter system. The
system powers local loads and when generation exceeds
load demand, excess power is exported to the utility for
net metering and other credits.
NOTE: Grid Tie is intended for use with systems that do
not include a Generac PWRcell Battery. For systems
where a Generac PWRcell Battery will be connected at a
later date, operate in Grid Tie mode until the battery is
installed.

Clean Backup

NOTE: Grid power is not used to charge batteries in this
mode.
See
Figure
2-6. In Clean Backup mode, the Generac
PWRcell Inverter prioritizes keeping the Generac
PWRcell Battery charged and ready for a grid interruption
using solar power only. If the battery is not fully charged,
the inverter uses all available solar power to charge the
battery.
See
Figure
2-7. When the battery is fully charged, solar
power will flow to local loads and the grid.
8
markets,
and
Table 2-1. Operational Inverter Modes
Clean Backup
Charge batteries from bus
Support local loads
Export to grid
-
Table 2-2. Optimal Mode for Goal
Priority Backup
Clean Backup
Grid Tie
Self Supply
Zero Export
Some modes interact with Generac PWRcell Batteries to
store power and/or balance production and consumption.
See
Table 2-1
and
Table 2-2
operational modes.
Priority Backup
Charge batteries from bus
Charge batteries from grid
Support local loads
Export to grid
Optimal Inverter Mode
Figure 2-6. Clean Backup (1 of 3)
Figure 2-7. Clean Backup (2 of 3)
Owner's Manual for Generac PWRcell Inverter
for an overview of available
Self Supply
Support local loads
Charge batteries from bus
Export to grid
-
009956
009957