If desired, a thermostat may be installed to regulate the Quadra-Fire DVI-32. It is important to use a thermostat designed for
millivolt operation. Do not connect this appliance to a thermostat serving any other appliance.
OPTIONAL THERMOSTATS
Manual Thermostat
Part #812-2880
Anticipator Setting 1.2
Electronic Setback
Part #811-0520
Connect the thermostat wires to the outer two screw terminals on the gas control valve, located behind the left side fascia access
panel. Turn off the manual switch located behind the right side fascia access panel.
A remote control or a wall switch may be wired to the thermostat terminals. Contact your Quadra-Fire dealer or service person
for details (see page 19 for part number).
The blower cord is located at the rear of the stove, and needs to be routed to a three-prong outlet with correct
polarity. Be sure that the stove is electrically grounded in accordance with local codes, with a current version of CSA
C22 (in Canada), or in the absence of local codes, with the National Electric Code ANSI/NFPA 70-1987.
f i r e - p a r t s . c o m
Do not route the power cord under the body of the appliance due to high temperatures.
The following procedures show some of the basic installation applications. Remember that every installation is
different, and the installer should adjust to insure that the appliance is installed properly.
The front brick shuttoff plate controls the secondary air supply to the burner tube. For NG stoves, it should be slid
all the way against the burner tube. For LP stoves, the front brick shutoff plate should be slid all the way to the front
of the stove.
Before hooking up the stove to the gas supply, be sure that the appliance you are installing is designed for the type
of gas being supplied to it. There is a serial number and listing label behind the gas supply access door behind the
left side fascia that will indicate which type of gas it is designed to utilize. The gas valve also has a label telling the
type of fuel for which it is set up.
There is a 3/8" gas hookup located behind the left side fascia access panel, at the valve. We recommend connecting
the stove with an approved flex gas line, as shown below. If flex gas lines are not approved in your area, you can
connect a hard pipe to the gas hookup. Be sure to comply with all local codes.
GAS CONNECTION
250-3692 (11/2000) DVi32 Gas Insert

THERMOSTAT INSTALLATION

REMOTE CONTROL

BLOWER POWER CORD

Do not cut the grounding terminal off under any circumstances.

INSTALLATION PROCEDURES

FRONT BRICK SHUTOFF PLATE ADJUSTMENT

GAS CONNECTIONS

FLEX LINE
RECOMMENDED MAXIMUM LEAD
LENGTH (TWO WIRE) WHEN USING
WALL THERMOSTAT/SWITCH
Wire Size
16 gauge
18 gauge
20 gauge
22 gauge
WARNING
FRONT
9
Maximum Length
65' (19.8m)
40' (12.2m)
25' (7.6m)
18' (5.5m)