Table 10. Acronyms Used on the HDSL2 Performance History Screens
Error Acronym
CV
ES
SES
UAS
LOSWS
U
P
SING THE
ERFORMANCE
To access the alarm history screens:
1
Press
P
to select the Performance screen.
2
Press the
SPACEBAR
HDSL2), then press
3
Press the
SPACEBAR
4
Press
N
or
P
to page through the alarm history screens.
5
Press
L
to clear the selected alarm history screen.
32
Description
Code Violation
Total count of HDSL2 CRC errors
Errored Seconds
Seconds with HDSL2 CRC
Severely Errored Seconds
Seconds with HDSL2 CRC
Unavailable Seconds
Based on 10 contiguous SES occurrences
Loss of Sync Word Second
Seconds with LOSW 1