Aiwa XP-ZV700 Service Manual page 21

Table of Contents

Advertisement

JACK BOARD IC401 SC901591AFR2
(FOCUS/TRACKING COIL DRIVE, SPINDLE/SLED MOTOR DRIVE, POWER CONTROL)
Pin No.
Pin Name
1
COM
2
VMU
3
UO
4
GNDUV
5
VO
6
VMVW
7
WO
8
GNDW
9
FO3
10
VM3
11
RO3
12
HBGND23
13
RO2
14
VM2
15
FO2
16
HBGND12
17
RO1
18
VM1
19
FO1
20
HBGND1
21
TEST
22
RSTB
23
SYNC
24
WAKE
25
COLDST
26
CLOCK
27
DATA
28
LATCHB
29
EXTRSTB
30
DCIN
31
CRF
32
CINM
33
BATM
34
CHGSW
35
RSOSCR
36
OSCC
37
RI3
38
FI3
39
RI2
40
FI2
41
RI1
42
FI1
43
CHGMON
I/O
I
Comparator (U/V/W) negative pole input terminal
-
Power supply terminal (for spindle motor drive U phase)
O
Spindle motor drive U phase output terminal
-
Ground terminal (for spindle motor drive U/V phase)
O
Spindle motor drive V phase output terminal
-
Power supply terminal (for spindle motor drive V/W phase)
O
Spindle motor drive V phase output terminal
-
Ground terminal (for spindle motor drive W phase)
O
Focus coil drive signal (+) output terminal
-
Power supply terminal (for focus coil drive)
O
Focus coil drive signal (-) output terminal
-
Ground terminal (for focus/tracking coil drive)
O
Tracking coil drive signal (-) output terminal
-
Power supply terminal (for tracking coil drive)
O
Tracking coil drive signal (+) output terminal
-
Ground terminal (for tracking coil drive and sled motor drive)
O
Sled motor drive signal (-) output terminal
-
Power supply terminal (for sled motor drive)
O
Sled motor drive signal (+) output terminal
-
Ground terminal (for sled motor drive)
-
Test mode terminal
O
System reset signal output to the system controller
I
176.4 kHz clock signal input from the system controller
I
Wake up signal input from the system controller
O
Cold start flag output to the system controller
I
Serial clock signal input from the system controller
I
Serial data input from the system controller
I
Command latch signal input from the system controller
I
External reset signal input terminal Not used
-
AC adapter power supply connection terminal
O
Battery charge circuit error amplifier output for rechargeable battery
I
Battery charge circuit error amplifier invert input for rechargeable battery
-
Rechargeable battery minus terminal (Except ZV700: AEP models only)
Battery charge control transistor drive signal output for rechargeable battery
O
(Except ZV700: AEP models only)
Connection terminal of sense resistor and external resistor for internal oscillation circuit
-
(Except ZV700: AEP models only)
-
External capacitor connection terminal for internal oscillation circuit
I
Focus servo drive signal (-) input from the system controller
I
Focus servo drive signal (+) input from the system controller
I
Tracking servo drive signal (-) input from the system controller
I
Tracking servo drive signal (+) input from the system controller
I
Sled servo drive signal (-) input from the system controller
I
Sled servo drive signal (+) input from the system controller
O
Charge voltage monitor output to the system controller
XP-ZV700/ZV701/ZV702
Description
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp-zv701Xp-zv702

Table of Contents