Wiring Diagram - Mitsubishi Electric PLFY-WP32VBM-E Technical & Service Manual

Ceiling cassettes
Hide thumbs Also See for PLFY-WP32VBM-E:
Table of Contents

Advertisement

6

WIRING DIAGRAM

PLFY-WP32VBM-E.UK PLFY-WP40VBM-E.UK PLFY-WP50VBM-E.UK
LEGEND
SYMBOL
NAME
I.B.
INDOOR CONTROLLER BOARD
CN27
CONNECTOR DAMPER
CN32
REMOTE SWITCH
CENTRALLY CONTROL
CN51
CN52
REMOTE INDICATION
CN105
IT TERMINAL
FUSE (T6.3AL250V)
FUSE
POWER SUPPLY (I.B.)
LED1
POWER SUPPLY (I.B.)
LED2
SW2
SWITCH
CAPACITY CODE
SW3
MODE SELECTION
SW4
MODEL SELECTION
DRAIN PUMP (TEST MODE)
SWE
X1
AUX. RELAY
DRAIN PUMP
A.B.
GRILLE
SW1
ON
MV MV MV MV
OFF
1 2 3 4 5 6 7 8 910
M
M
M
M
SW12 SW11
10s
5
5
5
5
DIGIT
20
18
16
14
12
10
8
6
4
19
17
15
13
11
9
7
5
3
VANE CNV
(WHT)
I-SEE SENSOR
MOTOR CN6Y
(RED)
1
6
MA REMOCON
CN3A
(BLU)
1
3
I-SEE SENSOR
CN4Y
(WHT)
1
4
CN52
CN51
(GRN)
(WHT)
1
5
1
4
5
M
I-SEE
SENSOR
MT
I-SEE SENSOR CORNER PANEL
(OPTION PART)
NOTES:
1. At servicing for outdoor unit, always follow the wiring diagram of outdoor unit.
2. In case of using MA-Remote controller, please connect to TB15. (Remote controller wire is non-polar.)
3. In case of using M-NET, please connect to TB5. (Transmission line is non-polar.)
4. Symbol [S] of TB5 is the shield wire connection.
5. Symbols used in wiring diagram above are,
6. The setting of the SW2 dip switches differs in the capacity. For the detail, refer to <Table 1> .
LED on indoor board for service
Mark
Meaning
Main Power supply (Indoor unit:220-240V)
Main power supply
LED1
power on → lamp is lit
Power supply for
Power supply for MA-Remote controller
LED2
on → lamp is lit
MA-Remote controller
OCH586
SYMBOL
NAME
DP
DRAIN PUMP
FS
DRAIN FLOAT SWITCH
MF
FAN MOTOR
MV
VANE MOTOR
TB2
TERMINAL
POWER SUPPLY
TRANSMISSION
TB5
BLOCK
TB15
MA-REMOTE CONTROLLER
THERMISTOR
ROOM TEMP. DETECTION
TH21
(0°C/15kΩ, 25°C/5.4kΩ)
TH22
PIPE TEMP. DETECTION/FROM
HBC UNIT (0°C/15kΩ, 25°C/5.4kΩ)
TH23
PIPE TEMP. DETECTION/TO HBC
UNIT (0°C/15kΩ, 25°C/5.4kΩ)
ADDRESS
4
CN43
(RED)
SWA
SWB
8
1
3
2
2
3
ADDRESS
1
4
CN82
(RED)
SW14
SWC
1
2
1s
BRANCH
1
DIGIT
No.
8
4
CN32
J42 J41
(WHT)
2
1
8
1
1
3
1
Pair No.
ADDRESS
ADDRESS
CN81
CN42 (RED)
(RED)
1
LED2
CN105
WIRELESS
CN90
(WHT)
1
9
CN41
(WHT)
1
4
5
9
TB15
ORN
BZ
TO MA-REMOTE
CNB
1
CONTROLLER
ORN
2
DC8.7-13V
SW1
LED2
SW2
LED1
RU
W.B.
: terminal block,
Function
SYMBOL
ADDRESS BOARD
A.B.
SWA
SWITCH
SWB
SWC
SW1
SW11
SW12
SW14
OPTION PART
W.B.
PCB FOR WIRELESS REMOTE CONTROLLER
BZ
BUZZER
LED (OPERATION INDICATION : GREEN)
LED1
LED (PREPARATION FOR HEATING : ORANGE)
LED2
RU
RECEIVING UNIT
EMERGENCY OPERATION (HEAT/DOWN)
SW1
EMERGENCY OPERATION (COOL/UP)
SW2
The black square (■) indicates a switch position.
<Table 1>
MODELS
SW2
ON
P32
OFF
1 2 3 4 5 6
ON
P40
OFF
1 2 3 4 5 6
ON
P50
OFF
1 2 3 4 5 6
See <Table 1>
SW3
SW4
SW2
ON
ON
OFF
OFF
4
1 2 3 4 5 6 7 8 910
1 2 3 4 5
1 2 3 4 5 6
SWE
5
OFF
ON
(RED)
3
AUTO GRILLE
CN25
CN3G
(WHT)
(BLK)
1 2
1
3
WATER PIPE
LED1
FROM HBC UNIT/
INTAKE
FLOAT SW
CN27
TO HBC UNIT
CN20
(RED)
CN4F
(RED)
CN44
(WHT)
(WHT)
1
4
1
4
1
2
1
2
*Be sure to turn off the source power
and then disconnect fan motor connector.
(Failure to do so will cause trouble in Fan motor)
TH22
TH23
FS
TH21
: connecter.
15
15
NAME
CEILING HEIGHT SELECTOR
DISCHARGE OUTLET NUMBER
SELECTOR
OPTION SELECTOR
MODE SELECTION
ADDRESS SETTING ONES DIGIT
ADDRESS SETTING TENS DIGIT
CONNECTION NO.
TB5
TO OUTDOOR UNIT
BLU
M1
BC CONTROLLER
BLU
REMOTE CONTROLLER
M2
DC24-30V
S
(SHIELD)
1 3
5
(BLK)
2 1
M-NET
CN2M
(BLU)
FAN
X1
CNMF*
(WHT)
3
1
7
4
1
D.U.M
CNP
(BLU)
3
MS
M
3~
1~
DP
MF
3
1
CN3G
AUTOMATIC FILTER ELEVATION PANEL
(OPTION PART)
POWER SUPPLY
~/N 220-240V 50Hz
220V 60Hz
BREAKER
(16A)
FUSE (16A)
TB2
RED
L
BLU
PULL BOX
N
GRN/YLW
TO NEXT
INDOOR UNIT
I.B.
CND
AUTO
GRILLE
POWER
3
1
CNAC
(WHT)
U.B.
CN3A
5 3
1

Hide quick links: