Output of setpoints to analog drives - retrofit solution
Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

2 SINAMICS HLA
Table 2-1 SINAMICS HLA interface description
Interface
X200 DRIVE-CLiQ
component
X201 DRIVE-CLiQ
component
X202 DRIVE-CLiQ
component
X203 DRIVE-CLiQ
component
X 224 electronic power
supply
X231/X232 TTL and SSI
encoders
X241/X242 pressure
sensors on the cylinder side
X251/X252 sensors
X261/X262 servo solenoid
valves
X271 26.5 V power supply
for the hydraulic
components
X272 shutoff valves
X281/X282 sensors for
shutoff valves
X291/X292 terminals to
enable the power
Sollwertausgabe an analoge Antriebe
Entry ID: 109761423,
V1.0,
• Connection to the
Control Unit
• Connection to the
previous SINAMICS HLA
Connection to the
previous Motor Module
• Connection to the next
SINAMICS HLA
Connection to the next
Motor Module
Encoder interface axis 1
Encoder interface axis 2
Power supply voltage of the
SINAMICS HLA
Operating a TTL or SSI
encoder.
TTL and SSI encoders
cannot be operated at the
same time on one slot.
Two pressure sensors are
provided for each axis to
determine the cylinder
pressure at the A and B
sides.
The sensors are used to
sense the pressure at the
shutoff valve.
This is the only interface to
the servo solenoid valve
and transfers the power
supply voltage, setpoint,
and actual value.
Power supply for the
hydraulic components
One shutoff valve is
connected for each axis
For especially safety-critical
applications, shutoff valves
can be used whose actuator
position is monitored using
sensors.
The power enable signal for
the SINAMICS HLA is
switched using the EP
terminals. Each channel of
the SINAMICS HLA is
equipped with its own EP
terminal.
10/2018
Use
Use in the application
-
-
-
-
-
-
Not for the 828 retrofit
solution
Not for the 828 retrofit
solution
On the 828 retrofit solution,
only the
analog setpoint is relevant.
Necessary for the 828
retrofit solution
Not for the 828 retrofit
solution
Not for the 828 retrofit
solution
Can also by supplied with
26.6 V to enable the
SINAMICS HLA, possibly
also switched via PLC
7