English
Condition
LEDs on Battery
Trimmer runtime is
too short.
Charge process does
1 LED glows red.
not start when
battery is inserted in
the charger.

18.2 Troubleshooting Charger

Condition
LED on Charger
Battery not being
LED flashes red.
charged.
52
Cause
Battery not fully charged.
Normal battery life has
been exceeded.
Battery too hot or too cold. ► Leave battery in the charger.
Cause
No electrical contact
between charger and
battery.
Malfunction in charger.
Remedy
► Fully charge the battery.
► Replace the battery.
Charge process starts automatically as soon as
permissible temperature range is reached.
Remedy
► Remove the battery.
► Clean contacts on charger.
► Fit the battery.
► Do not use the charger and contact your STIHL
servicing dealer.