Download Print this page

Trouble Shooting; Specifications - Delta breez SMT130 Installation And Operating Instructions

Ventilation fan
Hide thumbs Also See for breez SMT130:

Advertisement

WARRANTY
DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY
Delta Electronics Inc. (''Delta Electronics'') warrants to the
original consumer purchaser in the USA and Canada that
the Breez ventilation fan products will be free from
defects in material or workmanship. This warranty is
limited to three (3) years from the original date of
purchase.
Limitations and Exclusions
1. During the warranty period, a replacement for any
defective product will be supplied free of charge for
installation by the consumer. The warranty provided
herein does not cover charges for labor or other costs
incurred in the troubleshooting, repair, removal, and
installation service.
2. All returns of defective parts or products must include
the product model number, and must be made
through an authorized Delta Electronics distributor.
Authorized returns must be shipped prepaid. Repaired
or replacement products will be shipped by Delta
Electronics F.O.B. shipping point.
3. Delta Electronics shall not be liable for any indirect,
incidental, consequential, punitive, or special damages
arising out of or in connection with products use or
performance, regardless of the form of action whether
in contract, tort (including negligence), strict product
liability or otherwise.
4. The warranty does not cover if user does not comply
with manufacturer's installation manual.
5. To qualify for warranty service, you must notify Delta
Electronics at the address or telephone number below.
6. Delta Electronics shall have no liability to the original
owner-user with respect to any defect caused by
abuse, misuse, neglect, improper transportation or
storage, improper testing, improper installation,
improper operation, improper use, improper
maintenance, improper repair, improper alteration,
improper modification, tampering or accident of
products or parts thereof, or unusual deterioration or
degradation of products or parts thereof due to a
physical environment beyond the requirements of
products' specifications.
Address: 46101 Fremont Boulevard, Fremont, CA 94538
US Toll Free Number:
1-888-979-9889 - Technical Support
1-877-685-4384 - Customer Sales Support
www.deltabreez.com

TROUBLE SHOOTING

PROBLEM
POSSIBLE CAUSE
The fan is not turning on
1. Power off
2. Faulty switch
3. Faulty wire connection
The fan seems louder than it
1. CFM too great
should
2. Damper not working properly or
3. Bend in duct too close to fan
4. Fan discharge reduced to fit
5. Fan body not securely attached
The fan is not clearing the
1. Insufficient intake airflow within
room
2. Insufficient CFM
The light is not turning ON
1. Power off
2. Faulty switch
3. Faulty wire connection
The fan keeps running even
1. Our sensor tolerance is
though the house humidity
level is lower than user-
adjustable set-point.
2. Outdoor humidity is back

SPECIFICATIONS

Voltage
Frequency
Model No.
(V)
(Hz)
SMT130
SMT130H
SMT130M
SMT150
120
60
SMT150D
SMT150LED
Note: Specifications subject to change without notice.
4
CORRECTIVE ACTION
1. Make sure power supply is on.
2. Test or replace switch.
3. Check wire in switch box.
1. Be sure the CFM rating on the fan matches the
2. Check damper to ensure it is opening and
damaged
3. Be sure you do not have any sharp bends in
discharge
4. Use recommended size ducting to reduce fan
smaller duct
5. Be sure the fan is securely attached to your
1. Be sure a door or window is slightly ajar or
room
2. Be sure the CFM rating on the fan matches the
1. Make sure power supply is on.
2. Test or replace switch.
3. Check wire in switch box.
1. Continue to let the fan run since it is good to
+/- 10% RH
2. Turn the fan off when not in use.
drafting to the fan
Power
Air Flow
@ 0.1SP (W)
@ 0.1SP (CFM)
11.6
130
16.9
150
17.6
size of your room.
closing properly. If the damper has become
damaged, please call Customer Service.
duct closer than 18 in. to the fan discharge.
noise.
ceiling joists.
opened to allow airflow. The fan is not able to
draw air out of the room without enough
airflow to draw in from.
requirements for your room size.
keep venting the house and the electric bill is
minimal (approximately less than $10 per
year).
Max Current
Weight
Note
(amps)
(lb.)
Single Speed
Humidity Sensor
0.44
Motion Sensor
10.4
Single speed
0.47
Dual Speed
Single Speed
0.62
11.0
13 Watts, 850
Lumens, 3000K

Advertisement

loading