Replacing the processor
1
4
Figure 18: Mounting the heat sink
Ê Tighten the four screws crosswise. Follow the following steps:
1. Turn screw no.1 two/three turns, then will be no tension on the processor
when tightening the next screws.
2. Tighten screws no. 2, 3 and 4 in this order.
3. Tighten screw no.1 finally.
Tighten all screws as far as they will go with a torque of 0.6 NM.
Ê Close the server and connect all power plugs (for a detailed description see
the Options Guide).
I
After replacing the processor, it is recommended to update the BIOS to
ensure proper operation (BIOS flash diskette, for a description see the
BIOS Manual).