PREPARATION
LOAD BATTERIES (R03/LR03 x 2)
1. Press and slide
the lid.
2
2. Insert batteries.
Be sure to follow the
polarity markings indi-
1
cated in the compart-
3
ment.
3. Slide back the lid.
SET THE CURRENT TIME
1. Press the TIME
ADJUST button.
2. Press the
/
2
button.
3. Press the TIME
1, 3
ADJUST button.
REMOTE CONTROLLER HOLDER
To set the remote con-
1
troller in the holder
1. Insert.
2
2. Press in.
To take out the remote
1
controller from the
holder
2
1. Slide up.
2. Pull out.
MANUAL AUTO OPERATION
Use the MANUAL AUTO operation when the remote
controller is lost or unavailable.
Press
Press the MANUAL AUTO button on the main
unit control panel.
To stop operation, press the MANUAL AUTO button again.
NOTES
• Each press of the MANUAL AUTO button alternates
operation and stop.
• When the air conditioner is operated from the main
unit, it will operate under the same conditions as the
AUTO mode is selected on the remote controller.
• The fan speed is selected to "AUTO" and the tempera-
ture setting will be set to 23 °C.
Opr-wall-new remote2校
1
SLEEP TIMER
To set or change the SLEEP Timer
1. Press the
(SLEEP) button.
2. Press the
/
button.
Adjust the OFF TIME.
To cancel the SLEEP Timer
Press the
button.
Select
(TIMER RESET).
The air conditioner will return to normal operation.
MASTER CONTROL
Press the
button while in operation.
NOTES
AUTO
COOL
DRY
FAN
HEAT
(Select HEAT or
COOL automatically.)
TEMPERATURE
Press the
/
button while in operation.
Temperature setting range
NOTES
AUTO • • • • • • • 18 to 30 °C
HEAT • • • • • • • 16 to 30 °C
COOL/DRY • • • 18 to 30 °C
The thermostat setting should be considered a stan-
dard value, and may differ somewhat from the ac-
tual room temperature.
AIR DIRECTION (UPPER AND LOWER)
Press the
button while in operation.
For swing operation:
Press the
button while in operation.
Stop the setting by pressing it again.
NOTES
Range of swing
(1) The range of swing is relative to the currently
set airflow direction.
(2) During use of the Cooling mode, do not set
the VERTICAL air direction flap in 4 to 6 posi-
tion for long time, since water vapor may con-
dense near the outlet port and it may drip from
the air conditioner.
1, 2, 3 • • 1 to 4
1
2
4 • • • • • • • 3 to 5
3
5 • • • • • • • 4 to 6
4
6 • • • • • • • 1 to 6
5
6
NOTES
(1) The remote controller must be pointed at signal receiver to operate correctly.
(2) Operating range : About 7 meters.
(3) Beeping sound
• When a signal is properly received by the air conditioner, a beeping sound will be
heard twice.
• If an invalid signal is received by the air conditioner, a beeping sound will be heard 5
times.
• If no beeping sound is heard, press the remote controller button again.
(4) The buttons except the SLEEP, TIME ADJUST and ACL buttons can only be selected
while in operation mode.
OPERATION
ON / OFF TIMER
1. Press the
button.
Select
(OFF TIMER) or
NOTES
RESET
PROGRAM TIMER (OFF
2. Press the
/
button.
Adjust the OFF or ON TIME.
PROGRAM TIMER
To set or change the PROGRAM Timer
1. Press the
button.
Select
(OFF TIMER).
2. Press the
/
button.
Adjust the OFF time.
3. Repeat Step 1 and 2 to adjust ON time.
4. Press the
button.
Select
(PROGRAM TIMER).
(If the ON timer has been selected to operate
first, the unit will stop operating at this point.)
To cancel the PROGRAM Timer
Press the
button.
Select
(TIMER RESET).
The air conditioner will return to normal operation.
FAN SPEED
Press the
button while in operation.
NOTES
(Select the fan speed
automatically.)
AIR DIRECTION (RIGHT AND LEFT)
Press the
button while in operation.
For swing operation:
Press the
button while in operation.
START / STOP
Stop the setting by pressing it again.
Each press of the
Range of swing
NOTES
button alternates opera-
The range of swing is relative to the currently set
air flow direction.
tion and stop.
1
2
5
3
4
(5) PROGRAM timer
• The PROGRAM timer allows you to integrate OFF timer and ON timer operations
in a single sequence.
• The first timer function to operate will be the one set nearest to the current time.
(6) SLEEP timer
To prevent excessive warming or cooling during sleep, the SLEEP timer function au-
tomatically modifies the set temperature in accordance with the time setting. When
the set time has elapsed, the air conditioner completely stops.
(7) When connecting with other controllers, the indoor unit might be controlled by the
other controllers.
(8) The wired remote controller or the simple remote controller can also be used with this
unit.
04.3.16, 3:15 PM

CLEANING AND CARE

CLEANING THE INTAKE GRILLE AND THE
AIR FILTER
(ON TIMER).
1. Remove the intake grille and the air filter.
1 Place your fingers at the bottom of
OFF TIMER
ON TIMER
each side of the grille panel and
ON, OFF
ON)
lift forward. If the intake grille
seems to catch partway through
its movement, gently continue lift-
ing upward to remove.
2 Lift up the grille fully and remove.
3 Lift up the air filter's handle, disconnect the two lower tabs,
and pull out.
Air filter handle
Hooks (two places)
2. Cleaning
Intake grille : Remove dust with a vacuum cleaner, wash
the grille with warm water, and then dry with a clean and
soft cloth.
Air filter : Remove dust with a vacuum cleaner or by wash-
ing. After washing, be sure to allow it to dry thoroughly in
a shady place before reinstalling.
3. Replace the intake grille and the air filter.
1 Align the sides of the air filter
with the panel, and push in
fully, making sure the two
lower tabs are returned prop-
erly to their holes in the panel.
AUTO
HIGH
MED
LOW
2 Holding the intake grille hori-
zontally, fasten the two upper
hooks on the unit.
3 Press the intake grille down at
the lower sides to close.
NOTES
• When used for extended periods, the unit may accumulate dirt
inside, reducing its performance. We recommend that the unit
be inspected regularly, in addition to your own cleaning and
care.
For more information, consult authorized service personnel.
• Dust can be cleaned from the air filter either with a vacuum
cleaner, or by washing the filter in a solution of mild detergent
1 • • • 1 to 5 4 • • • 3 to 5
and warm water.
2 • • • 1 to 3 5 • • • 1 to 5
• When cleaning the unit, do not use water hotter than 40 °C,
3 • • • 2 to 4
harsh abrasive cleansers, or volatile agents like benzene or
thinner.
• Do not expose the unit to liquid insecticides or hairsprays.
• During periods of normal use, the air filters should be cleaned
every two weeks.
• When shutting down the unit for one month or more, first allow
the fan mode to operate continuously for about one-half day to
allow internal parts to dry thoroughly.
THE OPTIONAL AIR CLEAN FILTER
Install the optional air clean filter set as instructed.
The installation instructions are provided with the air clean
filter set.
Intake Grille
Hooks (two places)