Download Print this page
Fujitsu AS 18TF Series Operating Manual

Fujitsu AS 18TF Series Operating Manual

Wall mounted type

Advertisement

Quick Links

TM
OPERATING MANUAL
BEDIENUNGSANLEITUNG
MODE D'EMPLOI
MANUAL DE FUNCIONAMIENTO
MANUALE DI ISTRUZIONI
ΕΓΧΕΙΡΙ∆ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ
O
M
PERATING
ANUAL
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
AIR CONDITIONER
MANUAL DE INSTRUÇÕES
WALL MOUNTED TYPE
Indoor Unit
AS 18TF
AS 24TF
AS 30TF
KEEP THIS OPERATION MANUAL
FOR FUTURE REFERENCE
FUJITSU GENERAL LIMITED
P/N9371056012

Advertisement

loading

Summary of Contents for Fujitsu AS 18TF Series

  • Page 1 MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ∆ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ PERATING ANUAL РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ AIR CONDITIONER MANUAL DE INSTRUÇÕES WALL MOUNTED TYPE Indoor Unit AS 18TF AS 24TF AS 30TF KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9371056012...
  • Page 2 CONTENTS SAFETY PRECAUTIONS ........1 TROUBLESHOOTING ..........5 NAME OF PARTS ........... 2 OPERATING TIPS ........... 6 MANUAL AUTO OPERATION ....... 3 SPECIFICATIONS ........... 7 CLEANING AND CARE .......... 4 SAFETY PRECAUTIONS G Before using the appliance, read these “PRECAUTIONS” thoroughly and operate in the correct way. G The instructions in this section all relate to safety;...
  • Page 3 NAME OF PARTS Fig. 1 Fig. 2 SWING OPERATION TIMER SWING Fig. 3 Fig. 4 Fig. 1 Indoor Unit 9 Intake Grille (Fig. 4) 1 Operating Control Panel (Fig. 2) 2 MANUAL AUTO button 0 UP/DOWN Air Direction Flaps A Moving Diffuser 3 Indicator Lamps (Fig.
  • Page 4 MANUAL AUTO OPERATION Use the MANUAL AUTO operation in the event the remote control unit is lost or otherwise unavailable. Do not press the MANUAL AUTO button with wet hands or pointed objects, otherwise an electric CAUTION! shock or malfunction may occur. How To Use the Main Unit Controls Press the MANUAL AUTO button on the main unit control G When the air conditioner is operated...
  • Page 5 CLEANING AND CARE G Before cleaning the unit, be sure to stop the unit and disconnect the power supply. CAUTION! G Turn off the electrical breaker. G Be sure the intake grille is installed securely. G When removing and replacing the air filters, be sure not to touch the heat exchanger, as per- sonal injury may result.
  • Page 6 TROUBLESHOOTING Instructions relating to heating (*) are applicable to “HEAT PUMP MODEL” and “HEAT RECOVERY MODEL”. In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the elec- WARNING! trical breaker, and consult authorized service personnel. Merely turning off the unit’s power switch will not completely disconnect the unit from the power source.
  • Page 7 TROUBLESHOOTING Instructions relating to heating (*) are applicable to “HEAT PUMP MODEL” and “HEAT RECOVERY MODEL”. Items to check Symptom See Page G Has there been a power failure? Doesn’t operate at all: CHECK ONCE G Has a fuse blown out, or a circuit breaker been tripped? —...
  • Page 8 OPERATING TIPS Instructions relating to heating (*) are applicable to “HEAT PUMP MODEL” and “HEAT RECOVERY MODEL”. Temperature and Humidity Range Cooling/Dry Mode *Heating Mode Refrigerant Outdoor About 21 to 52 °C — COOLING ONLY MODEL temperature R407C About –15 to 52 °C HEAT PUMP MODEL About –15 to 52 °C About –15 to 21 °C...

This manual is also suitable for:

As 24tf seriesAs 30tf series