X111, X222 And X333 Digital Inputs/Outputs - Siemens NCU 7x0.3 PN Series Manual

Table of Contents

Advertisement

1
on
off
on
off
on
off
on
off
NOTICE
A newly set PROFINET address will only come into effect after power OFF/ON.
9.3.4.4

X111, X222 and X333 digital inputs/outputs

Cable specification
● Connectors: 50-pin ribbon cable connectors
● The required connecting cables (ribbon cables) must be provided by the user
● Max. cable length: 30 m
NCU 7x0.3 PN
Manual, 09/2011, 6FC5397-1EP40-0BA0
2
3
4
5
on
on
off
off
on
on
off
off
off
on
off
off
off
on
off
off
on
off
off
off
on
off
off
off
off
off
off
off
off
off
off
off
50-pin insulation displacement connectors with cable grip, ribbon cables and terminal
converters
are required for connecting digital inputs and outputs.
6
7
8
9
10
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
Connectable components
9.3 PP 72/48D 2/2A PN
Default device name
pp72x48pn7
pp72x48pn6
pp72x48pn5
pp72x48pn4
pp72x48pn3
pp72x48pn2
pp72x48pn1
pp72x48pn
.
125

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ncu 710.3 pnNcu 720.3 pnNcu 730.3 pnSinumerik 840d sl

Table of Contents