2. installation
location
ll PKA=A.HA(L)
2.1. Outline dimensions (indoor unit) (Fig. 2-1)
898
,
-
,
L
3. installing
the indoor
unit
(mm)
(inch)
Select
a proper
position
allowing
the following
clearances
for installation
and
maintenance.
m PKA-A.HA(L)
{D
Min.
150
Min. 50
Min. 50
Min. 250
Min. 5-29/32
Min. 1-31/32
Min. 1-31/32
Min. 9-27/32
(mm. inch)
(E}
Min. 220
Min. 8-21/32
(F
Air outlet:
Do not
place
an obstacle
within
1500 mm,
59-1/16
inch
of the air outlet.
(_
Floor
surface
(H Furnishing
(
When
the
projection
dimension
of a curtain
rail or the
like from
the
watl exceeds
60 ram,
2-23/64
inch
extra
distance
should
be taken
because
the fan
air current
may
create
a short
cycle,
(J"
1800 mm,
70-7/8
inch
or greater
from
the floor
sunace
(for high
location
mounting)
(k
55 mm,
2-11/64
inch
or greater
with
left
or rear
left piping
and
optional
drain
pump
installation
(L
550
mm,
21-21/32
inch
or greater
with
optionat
drain pump
installation
(M Minimum
7 mm,
9/32
inch:
250
mm,
9-27/32
inch
or greater
with
optional
drain
pump
installation
:::_}
::@
::g
::_}
%%
Fig. 3-1
m PKA-A.HA(L)
3.1. Check the indoor
unit accessories
(Fig. 3-1)
The
indoor
unit should
be supplied
with the following
accessories.
PART
ACCESSORY
NUMBER
Mount
board
1
_i
Tapping
screw
4 x 35
12
_i
Felt tape
3
_i
Band
3
_
Wireless
remote
controller
1
_i
Remocon
holder
1
ZI
Alkali
batteries
(size AAA)
2
_i
Tapping
screw
3.5 x 16
2
Block
of cushion
1
c_
Wired
remote
controller
ili
Remote
controller
cable
QUANTITY
PKA-A.HAL
PKA-A.HA
1
12
3
3
1
1
1
LOCATION
OF
SETTING
Fix at the back of
the unit
3.2. Installing
the wall mounting
fixture
(Fig. 3-2)
3.2.1.
Setting
the
wall
mounting
fixture
and
piping
positions
I_ Using
the wail
mounting
fixture,
determine
the unit's
installation
position
and
the locations
of the piping
holes
to be drilled.
Z_ Warning:
Before drilling
a hole in the wall, you must consult the building
contractor.
PKA-A.HA(L)
Mount board
B Indoor unit
Bottom left rear pipe hole (e65 ram, 2-9/16 inch)
b Bottom right rear pipe hole (e65 mm, 2-9/19 inch)
E} Knockout hole for left rear hole (70 mm, 2-3/4 inch x 310 ram, 12-13/14 inch)
F Bolt hole (4-e9 mm, 23/64 inch hole)
Center measurement
hole (e2.5 ram, 3/32 inch hole)
H Tapping hole (77-_5.1 ram, 13/64 inch hole)
i
Hole centre
J
Align the scale with the line,
k
Insert scale,
3.2.2.
Drilling
the
piping
hole
(Fig.
3=3)
I_ Use a core
drill
to make
a hole of 65-80
ram, 2-9/16-3-5/32
inch
diameter
in
the wall in the piping
direction,
at the position
shown
in the diagram
to the
left.
I_ The
hole
should
incline
so that
the outside
opening
is lower
than
the
inside
opening.
I_ insert
a sleeve
(with
a 65-80
mm,
2-9/16-3-5/32
inch
diameter
and
purchased
locally)
through
the hole.
(
Sleeve
(B Hole
(Indoors)
b
Wail
(E} (Outdoors)
Note:
The purpose
of the hole's
inclination
is to promote
drain
flow.
3