7. Test run
[Output
pattern
B[
Errors
detected
by unit other
than
indoor
unit (outdoor
unit, etc.)
Wireless
remote
controller
Beeper
sounds/OPERATION
INDICATOR
lamp flashes
(Number
of times)
1
2
3
4
5
6
7
8
9
10
11
Wired
remote
controller
Check
code
Symptom
Remark
E9
Indoor/outdoor
unit communication
error
(Transmitting
error)
(Outdoor
unit)
UP
Compressor
overcurrent
interruption
U3, U4
Open/short
of outdoor
unit thermistors
UF
Compressor
overcurrent
interruption
(When
compressor
locked)
U2
Abnormal
high discharging
temperature/49C
worked/insufficient
refrigerant
U1, Ud
Abnormal
high pressure
(63H worked)/Overheating
safeguard
operation
U5
Abnormal
temperature
of heat
sink
For details,
check
the LED
U8
Outdoor
unit fan safeguard
stop
display
of the outdoor
controller
U6
Compressor
overcurrent
interruption/Abnormal
of power
module
board.
U7
Abnormality
of super
heat due to low discharge
temperature
U9, UH
Abnormality
such
as overvoltage
or voltage
shortage
and abnormal
synchronous
signal
to main circuit/Current
sensor
error
12
-
-
13
-
-
14
Others
Other
errors
(Refer
to the technical
manual
for the outdoor
unit.)
"1 If the beeper
does not sound
again
after the initial two beeps
to confirm
the self-check
start
signal
was received
and the OPERATION
INDICATOR
lamp does not come
on, there
are no error
records,
*2 If the beeper
sounds
three
times continuously
"beep,
beep,
beep (0.4 + 0.4 + 0.4 sec.) '_after the initial two beeps
to confirm
the self-check
start signal
was received,
the
specified
refrigerant
address
is incorrect.
• On wireless
remote
controller
The continuous
buzzer
sounds
from
receiving
section
of indoor
unit.
Blink of operation
lamp
• On wired
remote
controller
Check
code displayed
in the LCD.
If the unit cannot
be operated
properly
after the above
test run has been performed,
refer to the following
table to remove
the cause.
Symptom
Wired
remote
controller
For about
2
PLEASE
WAIT
minutes
following
power-on
PLEASE
WAIT
_ Error code
After about
2
minutes
has
expired
following
Display
messages
do not appear
even
power-on
when operation
switch
is turned
ON
(operation
lamp does
not light up).
On the wireless
remote
controller
with condition
above,
following
phenomena
takes
place.
• No signals
from
the remote
controller
are accepted.
• OPE
lamp is blinking.
• The
buzzer
makes
a short
pipng sound.
LED
1,2
(PCB in outdoor
unit)
After
LED
1,2 are lighted,
LED 2 is turned
off,
then
only LED
1 is lighted.
(Correct
operation)
Only
LED
1 is lighted.
_ LED
1,2 blink.
Only
LED
1 is lighted.
_ LED
1 blinks
twice,
LED
2 blinks
once.
Cause
For about
2 minutes
following
power-on,
operation
of
the remote
controller
is not possible
due to system
start-up.
(Correct
operation)
Connector
for the outdoor
unit's
protection
device
is not
connected.
Reverse
or open phase
wiring
for the outdoor
unit's
power
terminal
block
(L1, L2, GR)
Incorrect
wiring
between
indoor
and outdoor
units
(incorrect
polarity
of Sl,
$2, $3)
Remote
controller
wire short
Note:
Operation
is not possible
for about
30 seconds
after
cancellation
of function
selection.
(Correct
operation)
For description
of each
LED (LED
1, 2, 3) provided
on the indoor
controller,
refer to the following
table.
LED
1 (power
for microcomputer)
Indicates
whether
control
power
is supplied.
Make
sure that this LED is always
lit.
LED 2 (power
for remote
controller)
Indicates
whether
power
is supplied
to the remote
controller.
This LED
lights
only in the case
of the indoor
unit which
is connected
to the outdoor
unit refrigerant
address
"0".
LED 3 (communication
between
indoor
and outdoor
units
only A-control)
Indicates
state of communication
between
the indoor
and outdoor
units.
Make sure
that this
LED is always
blinking.
13