IBM 3708 Planning And Installation page 148

Network conversion unit
Hide thumbs Also See for 3708:
Table of Contents

Advertisement

Recognize System Request Simulation
Text Time Out
[0 - 3]
0- This function is disabled.
I-The 3708 recognizes string 1 (defined in the Chapter 14, "Defining the
General Definition").
2-The 3708 recognizes string 2 (defined in the Chapter 14).
3-The 3708 recognizes the default string (99999).
The system request simulation string (options 1,2, or 3) is recognized only when it
occurs at the beginning of a line of data. The rest of the line is then transmitted to
the SSCP. The SSCP message can be up to 251 bytes long and must end with a
defined line turnaround character.
Note: If you specify 1, 2, or 3, the data received after the specified string is sent on
the SSCP - LU session after a line turnaround is received.
[000 - 255]
Type the time, in half seconds, that the 3708 is to wait before assuming a turnaround
character and before sending data to the host. Typing 000 indicates no text time
out.
The recommended value for this field is 000.
Permanent Request To Send
[1,0]
(}-Operating in half duplex facility
l-Operating in full duplex facility
See "Full Duplex Line" on page 13-36.
Turnaround Characters
[X'Ol' - X'FF']
Up to five different line turnaround characters can be defined. To define the line
turnaround characters, type the hexadecimal representation of each of the EBCDIC
characters. X' 00' indicates the end of the field. If no translation is defined
(TRANSLATE
=
0) type the hexadecimal representation of the line turnaround
characters.
Each character is accepted as a turnaround character and as the ENTER key during
3708 logon. For example, the default value for this field is X'OD25000000', which
defines two different line turnaround characters. (X' OD' is carriage return and
X' 25' is line feed.)
Chapter 13. Configuration Procedures